Key points for safe operation of large-scale cold storage refrigeration operators
The main points of safe operation are as follows:
1, safe operation regulations
Generally, there should be safety operating procedures for the machines and equipment of refrigeration installations, and refrigeration operators must strictly follow them to ensure safe production.
2. Familiar with the entire refrigeration system
The refrigeration operator must be familiar with the whole set of refrigeration process system diagrams of our factory (unit), and should be familiar with the names and specifications of the main equipment.
3. The refrigeration operators in the computer room should achieve "four requirements", "four diligence" and "four timely".
① "Four essentials" must ensure safe operation, ensure warehouse temperature, reduce condensing pressure as much as possible, and fully develop
Improve the cooling efficiency of the equipment.
②"Four Qin": look at the instrument frequently, check the temperature of the machine, listen to the sound of the machine, and understand the warehouse in and out
Happening.
③"Four in time": timely drain oil, timely flush frost, timely release air, and timely clean condenser scale.
4, the valve opens slowly
Various valves on machinery and equipment pipelines should be opened slowly when opening.
5. Constant water
When the compressor is running, the condenser must not be cut off (stop running)
6, the liquid level is maintained at the specified value
The liquid level of the high-pressure reservoir shall neither exceed 80% nor less than 30%.
7, protect
When performing operations such as adding ammonia or draining oil to the refrigeration system, the refrigeration operator should wear rubber gloves and a gas-proof surface
tool to prevent burns on hands and face.
8. Avoid opening by mistake
For the standby valve (regulation station, etc.) that is open to the atmosphere, the ammonia valve or the sewage (oil discharge) set in the quick freezing room
valve, the hand wheel should be removed at ordinary times to avoid opening by mistake.
9, hanging up and closing signs
In order to avoid misoperation, the position and purpose of each control valve of the regulating station should be marked, and the handwheel of each valve should be
Open and close cards.
10. Make a record
The operation and maintenance of the compressor should be recorded in a timely and correct manner.

Related Info
How to properly use central air conditioning during the epidemic Just read this one How to solve the air conditioner failure HVAC people collect these data, better than ten years of work experience! Ice machine installation and commissioning guidelines and installation service process Is the refrigerant gas or liquidKey points for safe operation of large-scale cold storage refrigeration operators
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
Kompass Vane Pump VE1E1-4040F-A2
Contact Us
COKERY Belt C102
US$23.08
Copeland Compressor ZB76K5E-TF3
Contact Us
TORRINGTON Bearing B-1210-OH
US$17.31
XINJE TouchWin HMI TH465-UT
US$250.00
PARKER Filter 933743Q
US$41.54
CKD Air Cylinder SCPD3-L-CB-16-75-T2V3-D
Contact Us