Tips for quick maintenance of refrigeration system
Today, let’s take a look at a few tips for overhauling refrigeration and air conditioning systems, which are very useful to everyone!
1. The press does not start, and there is no problem with the temperature setting, but there is no response after power on
The compressor does not turn, the fan turns, you must first look at the capacitor
The capacitor bulge needs to be replaced. Remove the capacitor and check the power supply
If there is power supply, check the press machine, overload protection is the key
There is no power supply to the house, first check the connection line
Secondly, look at the temperature control. The temperature control should be replaced
Relay is an important point, the front driver must be judged
If the above is normal, the following things are easy to handle
Mainboard repair or replacement, ask the user before making a decision
2, heat protection after the press starts
There is cold air when the air conditioner is turned on, the temperature then increases
After a while, the cold wind turns to hot, and the outside press stops.
At this time, look at the external fan first, whether the speed is low or not
If it is low, change the capacitor instead of the capacitor for the fan
Next, look at the condenser, if it is too dirty, it needs to be cleaned
Too much fluorine is added and the current is large, the press will also stop work
The capacitor of the press machine also depends on it. It is best to change according to the original machine
3, the press will be protected in a few seconds after power on
Disconnect the power supply line of the compressor and judge by the external line
If check the power supply normally, replace the capacitor first
Change the capacitor and experiment again, if you make money normally
On the contrary, cut off the high voltage and turn on the high voltage and try again
If the compressor runs normally, the pipe is blocked is the key
If the press has not been transferred yet, replace the press
Note: After the press is protected, the overload protector will not reset until a while, so the press will not respond when the power is turned on immediately.
4, the air conditioner turns on when it is turned on
Don’t mess with this beforehand, disconnect the external connection line
It's good to judge inside or outside, and work well when judged
Easy to deal with external machine failures, four-way press and fan
One by one, break the wires one by one, change which one is broken
Finally, check the connection cable. The mouse gnawed and leaked
Internal machine failure is difficult to handle, the fan wind swing is judged first
Take out the motherboard and take a closer look to see if there is UMC
It’s really hard to repair the board and change it, making money is the key
5. The air conditioner is not cooled well or is not cooling
This problem is the most common air conditioner lack of fluoride is the key
First touch the air pipe when power on, judge by temperature
If it is cold, check the internal machine, the fan speed may be low
inner tube scales and dustproof, clean or replace
If the inner tube is not cold, the thick tube may be flattened
The return air temperature is not cold, then touch the air to judge
The intake air is cold and frosty, add fluoride and try again
If the frosting slowly dissipates, it will be fluorine-deficient and good decision
It is not difficult to see the aging of the press. Insufficient exhaust is the key point
Four-way gas cross-talk is also common. Judging by collecting fluorine
High-pressure scales must be watched, they will slow down if they are dirty
6. The air conditioner does not turn on
The air conditioner is energized to test it according to the beep
There is no beep to check the power supply. Next, look at the motherboard
If there is a beep, then judge
Air conditioner startup is easy to handle, judge the remote control damage first
Exclude remote control check reception, infrared reception first replace
Check again if there is power supply, follow the signal line again
Then power on and experiment again to see if the air conditioner works
If the air conditioner doesn’t turn on
Note: Most air conditioners will make a beep when they are powered on, but there are some, you can judge by yourself.

Related Info
The role of refrigerant in air-cooled chillers The top ten coal-to-electricity installation misunderstandings this winter may cause air source manufacturers to stumble Three maintenance and inspection methods for air-conditioning refrigeration compressors Three-step strategy to extend the service life of chillers Tips for quick air conditioningTips for quick maintenance of refrigeration system
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
Kuebler Encoder 8.5020.7541.1024
Contact Us
Danfoss Compressor SZ090S4VC
US$2168.36
Bristol Compressor H20B203ABC
US$563.38
PARVEX Servo Motor RX320ER500C
Contact Us
Daikin Air Conditioner FQFSP28ABN
US$1615.00
Festo Air Cylinder DSBC-40-15-PPVA-N3
US$164.45
PIZZATO Switch FP 1451
US$161.54
CML Overflow Valve BSG-06-3P-3
US$427.31