What is the cause of refrigerator compressor not working

What is the cause of refrigerator compressor not working Ambient temperature is too low: it is more difficult to recover, the compressor cannot work for a long time, the compressor oil becomes thicker, and the lubrication performance will be worse; PTC starter failure: if the PTC starter is damaged, you can replace it Overload protector failure: failure occurs, replace it; compressor internal failure: determine that the compressor holds the shaft and replace it. We know that the refrigerator is an indispensable appliance in the home. Due to the high frequency of use, it will be prone to some failures after a long time. At this time, we must find the cause and deal with it. The following editor will introduce the reason why the refrigerator compressor does not work. 1. The ambient temperature is too low a. If the ambient temperature is at (1~10℃), then you need to open the compensation switch at this time, and you need to check whether the magnetic switch is normal: to know that the temperature may be too low, especially for some dual-temperature single-control refrigerators As long as the working time is too short and its refrigerating temperature reaches (1~10℃) degrees, then the temperature will be more difficult to rise in this case, the compressor cannot work for a long time, and the shutdown may be too long , It may cause non-working. b. When the ambient temperature is 0 ℃, then you must stop using the refrigerator: when the temperature is 0 ℃, this time may make the compressor oil thicker, the lubrication performance may be worse; at the same time It is possible that the condensing pressure will also decrease, and the refrigerant will flow into the evaporator. 2. Failure of the PTC starter You can use a multimeter to measure the PTC starter. At this time, you can see whether its running jack and start jack are normal. If the PTC starter is damaged, you can replace it. 3. Overload protector failure You can use an ammeter to measure the compressor startup, and also check the running current. If the current exceeds the action of the protector, there may be a malfunction and it should be replaced. 4. Internal fault of the compressor If the testing of the compressor accessories is normal, but the compressor still cannot be started at this time, then you may have too much starting current during the measurement. At this time, you can judge it as the compressor holding the shaft. In this case It is necessary to replace the compressor.

Recent related posts

Customers frequently viewed

New In stock for sale, IWAYA DENKI Water Pump 25CJT0752

IWAYA DENKI Water Pump 25CJT0752

US$2307.69
New In stock for sale, ROTEN Mechanical Seal 8E5K-22-X

ROTEN Mechanical Seal 8E5K-22-X

US$384.62
New In stock for sale, Delta Servo Motor ECMA-G11309PS

Delta Servo Motor ECMA-G11309PS

Contact Us
New In stock for sale, LYC Bearing NU1013

LYC Bearing NU1013

US$126.92
New In stock for sale, WINBOND IC W972GG6KB-25 TR

WINBOND IC W972GG6KB-25 TR

US$36.27
New In stock for sale, PENTAX Water Pump CM32-250A

PENTAX Water Pump CM32-250A

US$3579.62
New In stock for sale, Danfoss Expansion Valve 067N6018

Danfoss Expansion Valve 067N6018

US$194.62
New In stock for sale, EZO Bearing 689-RS

EZO Bearing 689-RS

US$10.00
New In stock for sale, Balluff Sensor BES053A

Balluff Sensor BES053A

US$125.60