Why should the high and low temperature test chamber be debugged and calibrated? In order for the high and low temperature test chamber to exert its maximum efficiency and stability in the hands of customers, the most important thing is to debug and calibrate the factory during the 15-day forward behavior period. The following are the three methods for calibrating the high and low temperature test chamber and their The advantages and disadvantages of: 1. The advantage of calibrating this method under no-load conditions is that the entire working area of the high and low temperature test chamber has been calibrated, and the applicability of the high and low temperature test chamber can be effectively evaluated. The main disadvantage is that it cannot evaluate the impact of the test sample on the test chamber. 2. Calibration under load conditions: The advantage of this method is that it can more accurately evaluate the impact of the test sample on the performance of the test box, and it is easy to obtain the detailed information of the environmental test of the key components or parts of the test sample. The main disadvantage is that when the test sample is changed, it needs to be recalibrated. 3. Real-time measurement during use: This method not only has the advantages of the above method. Moreover, the comprehensive environmental parameters of the test sample in the environmental process can be obtained, which is often used in product tests with high environmental requirements. Its main disadvantages are: measurement equipment is required for each environmental test, and the calibration method under no-load conditions is usually used in the calibration of the test chamber. Through the above method to debug and calibrate the high and low temperature test chamber, we can try to simulate a more reliable test environment, so as to make accurate analysis and evaluation of the sample.
Why should the high and low temperature test chamber be debugged and calibrated?
Recent related posts
-
07/16/2020
Why should the high and low temperature test chamber be debugged and calibrated?
In order for the high and low temperature test chamber to exert its maximum efficiency and stability in the hands of customers, the most important thing is to debug and calibrate the factory during the 15-day forward behavior period. The following are the three methods for calibrating the high and low temperature test chamber and their The advantages and disadvantages of
-
07/16/2020
How to repair the vacuum drying oven
During the use of the vacuum drying oven, the heating tube will accumulate a high amount of heat in a short period of time, so pay attention to the even heat dissipation during use, that is, you must turn on the blower after starting the heating. For heating conditions, first check whether the control instrument is working normally
-
07/16/2020
How to clean the constant temperature and humidity box condenser
The condenser of the constant temperature and humidity test chamber should be maintained regularly on a monthly basis. Use a vacuum cleaner to absorb the dust adhering to the condensing heat dissipation mesh or use high-pressure air to remove the dust.
-
07/16/2020
How to see if the refrigerant leaks in the high and low temperature test chamber
How to check whether the refrigerant leaks in the high and low temperature test box; the standard high and low temperature test box and the constant temperature and humidity test box are all selected by the air-cooled compressor, and the working principle is the same as that of the air conditioning refrigeration
-
07/16/2020
What should I do if there is ice jam in the cold and hot shock test box?
During the environmental test, the thermal shock series and the thermal shock test chamber may have many problems, which may cause ice jams. How to solve this problem? Some people think that when large equipment such as the thermal shock series appears The problem, most people may think that only * maintenance personnel can perform repairs, but this is not the case. Stress screening cold and hot shock test box
-
07/16/2020
Analysis of the reason why cold storage should not be built underground
Many people think that building cold storage underground will have better thermal insulation effect than cold storage on the ground, because in the past, when the technology was backward, it was very common to choose cellars as crop storage. But from a commercial point of view, it is not scientific to blindly build the cold storage underground. The cold storage construction team stands from the perspective of consideration for customers
-
07/16/2020
Three factors determine the quality of cold storage
The size of the cold storage should be designed according to the highest amount of agricultural products to be stored throughout the year. This capacity is calculated based on the volume that the stored products must occupy in the cold storage, plus the aisles between the rows, the space between the stack and the wall and ceiling, and the gap between the packaging.
-
07/16/2020
Judgment of the failure of piston compressor in starting
Piston compressor It is a type of compressor commonly used in industrial refrigeration. Most piston compressors use a semi-closed shape, which is simple and convenient to maintain and repair. It is widely used in large supermarkets, cold stores, laboratories, and various refrigeration equipment.
-
07/16/2020
Common failures and maintenance of overload protectors for air-conditioning compressors
Overload protector of air conditioner compressor Installed between the active and passive sides of the power transmission, when an overload fault occurs (torque exceeds the set value), the torque limiter will separate, thereby effectively protecting the driving machinery and the load. Just like its name, the fundamental function of the overload protector is to protect the air-conditioning compressor.
-
07/16/2020
Main features of semi-closed scroll compressor
1. On-site maintenance: The shell of the half-sealed scroll compressor can be disassembled, and the horizontal cast iron body is fixed by bolts. 2. Patented flexible scroll technology: compact structure, extremely low vibration-quiet operation and higher tolerance to liquids and magazines.