There is no price at present, you can Request a Quote
OSHON Vane Pump VDC-2B-F54-D-20
There is no price at present, you can Request a Quote
People who bought this item also viewed
Yuci Vane Pump PFED-42070-008-1DT
TOKYO KEIKI Vane Pump SQP3-32-86-C-18
TOKYO KEIKI Vane Pump SQP21-21-3-86CD-18
Yuci Vane Pump YB-A6B-DU-FL-50
HNC Proportional Valve EBG-10-C-L
KOMPASS Check Valve MPB-04-C
ASHUN Overflow Valve RV-03G-B-10
HAWE Piston Pump R0.43
Honor Gear Pump 2MM1F22
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Siemens Sensor QBM4100-1U
INFINEON IGBT Module FGA25N120
SBC Linear Guideway SBS35HLL-C-K1
CHINT Fuse RT28-32 32A
YUKEN Piston Pump A100-FR01BS-60
Mean Well Power Supply HRPG-450-24
Recent related posts
-
03/28/2024
What Are the Components of Industrial Robots?
Industrial robot is a multi-joint manipulator or multi-degree-of-freedom mechanical device widely used in industrial fields. It has a certain degree of automation and can realize various industrial processing and manufacturing functions.
-
08/21/2023
Swimming Pool Heat Pump: Definition, Working Principle and Benefits
If you're a pool owner, you know that keeping your pool at the perfect temperature is crucial for a comfortable and enjoyable swimming experience.
-
06/13/2020
Refrigeration compressors can be divided into two types
Refrigeration compressors can be divided into two types: volume type and speed type according to their working principles
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
01/09/2024
Cooling Towers: Operation Methods, Maintenance & Usage Precautions
Cooling towers are critical equipment used in industrial and commercial areas to cool fluids. In order to ensure its effective operation, increase its lifespan and maintain safety, correct operation methods, maintenance and upkeep knowledge, and usage precautions are crucial. In this article, we will delve into these aspects.
-
07/15/2020
What you need to know about the electrical connection of Copeland refrigeration compressors
Please pay attention to the direction of the terminals in the junction box (single-phase: R, S, C; three-phase: T1, T2, T3). In order to ensure the normal start-up and operation of the Copeland refrigeration compressor, the power supply voltage cannot be lower than 10% of the Copeland compressor rated voltage.
-
07/04/2020
How important is the air conditioning compressor for air conditioning
How important is the air conditioning compressor for air conditioning As the earth we live in enters summer, the summer in many places is uncomfortably hot, so a good summer cool companion to accompany them is-air conditioning. Air conditioning has become a good weapon for us to spend the summer.
-
06/20/2020
Composition principle of refrigeration system of refrigerator
Composition principle of refrigeration system of refrigerator Refrigerators have a larger cooling capacity than household refrigerators, and there are more refrigerants filled in the system. Therefore, a liquid storage tank is installed on the pipeline between the condenser and the filter, and a shut-off valve is installed on the tank to shut down the system for a long time. When closing the shut-off valve, the refrigerant liquid is stored in the tank.<img src="{{media url="Composition_principle_of_refrigeration_system_of_refrigerator.jpg"}}" alt="" />
-
07/17/2020
Reasonably adjust the cold storage evaporator and defrost in time
Reasonably adjust the cold storage evaporator and defrost in time Generally speaking, every increase in the cold storage evaporation temperature can save energy Therefore, under the premise of satisfying the low refrigeration process of the product, the evaporation temperature can be increased as much as possible by adjusting the amount of liquid supplied. The thermal resistance of the frost layer is generally much larger than the thermal resistance of the steel pipe.
-
08/12/2020
Precautions for the use of ultra-low temperature storage boxes
The ultra-low temperature storage box is shipped after more than 12 hours of debugging before leaving the factory. Today, the editor of the ultra-low temperature storage box okmarts.com will share with you, there are some problems that should be paid atte¨ﰨ2 䀀 湠疨 V ǜ