OSHON Vane Pump VPVCC-F3030-A4A4-02
People who bought this item also viewed
Rexroth Vane Pump PVV4-1X-098RA15LMC
Kompass Vane Pump VD2-25F-A4
TOKYO KEIKI Vane Pump SQP2-21-1A-18-P
SMC Proportional Valve ITV3050-344L3
KOMPASS Check Valve CPDT-10-A2
NORTHMAN Overflow Valve DRF-G06-4
YUCI Piston Pump A37-F-R-01-H-S-K-32
HYTEK Gear Pump CP0-63-P-10R
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTac Solenoid Valve 4M11006A
SHAKO Air Cylinder IC32B100
OMRON Relay G3FD-102SN AC200/220
Recent related posts
-
06/21/2020
[Experience] What happens if the compressor suction pressure is too high and the discharge pressure is too high
[Experience] What happens if the compressor suction pressure is too high and the discharge pressure is too high Compressor suction pressure is too high, discharge pressure is too high 1. Too much refrigerant. Too much refrigerant will cause the suction pressure and discharge pressure to be too high at the same time. This is because when too much refrigerant fills the reservoir, it will occupy a part of the condenser volume, reducing the heat dissipation area and causing the condenser Poor condensation. Discharge excess refrigerant from the low-pressure side.
-
06/25/2020
The air conditioner suddenly stopped cooling.
1.The air conditioner remote control may not adjust the temperature. 2. It may be that the air conditioner has not been cleaned for too long, which causes dust to accumulate on the filter net, so that the cold air blocking the air conditioner cannot be blown out. 3. There may be leakage of freon in the air conditioner, resulting in too little freon, and the air conditioner is not cooled. 4. Energy saving is due to unstable voltage, which causes the air conditioner to not be cooled. 5. It may be that the number of air conditioners is insufficient, and the small number of horses is not used for cooling in a large area of the house.
-
07/19/2020
Advantages of adding economizer to screw chiller
The temperature control range of the standard screw chiller is 3~35℃, and the efficiency is significantly reduced when operating under lower temperature conditions. In order to meet the temperature requirements of more industries for chillers, make the single-stage screw compressor work according to the two-stage refrigeration cycle and achieve the effect of energy saving, an economizer can be added to the unit.
-
06/14/2020
Advantages of natural gas used in air conditioning and refrigeration technology
Advantages of natural gas used in air conditioning and refrigeration technology Natural gas-based refrigeration and air-conditioning technology has entered the market in developed countries in the middle of the last century.
-
09/15/2020
Reasons and necessity of overhaul of oil-injected twin-screw air compressor
The structure of the main engine (also known as the head) of an oil-injected twin-screw air compressor is usually composed of a pair of mutually meshing screws, main engine casing, high-pressure end and end cover, and low-pressure end and end cover.
-
12/03/2023
Notebook Cooling: Function Analysis of Thermal Grease, Heat Pipe and Cooling Fins
In the cooling module of the notebook, the three most critical elements are the heat pipe, the cooling fan and the cooling fins, and there are also elements used to improve the contact area and heat transfer efficiency between them.
-
06/13/2020
Refrigeration compressor configuration application and precautions
Compressor configuration Generally speaking, semi-hermetic compressors are equipped with: oil filter, oil hole, exhaust with pressure gauge interface, suction cut-off valve, suction filter, sight glass.
-
06/29/2020
Semi-closed piston refrigeration compressor 4SJH-3000
Semi-closed piston refrigeration compressor 4SJH-3000 Features of semi-hermetic piston compressor 4SJH-3000: 1. Light in size and small in space 2. Suitable for R12, R22 and R502, with a wide range of applications
-
06/13/2020
11 common protection devices for refrigeration compressors
11 common protection devices for refrigeration compressors When the compressor is running, some abnormal conditions may occur, such as: the discharge pressure is too high
-
08/25/2020
Renovation of the small turbine of the propylene refrigeration compressor oil station of the DCC unit has achieved initial results
Recently, the technicians of the DCC device have undergone transformation. The temperature of the small turbine bearing box of the propylene compressor oil station of the device has dropped from 90-120 degrees Celsius to 70-85 degrees Celsius