There is no price at present, you can Request a Quote
PHILIPS Resistor MRS25 0.25W 54.9K
There is no price at present, you can Request a Quote
People who bought this item also viewed
Ferraz Shawmut Fuse BS36UG25V100P
TYCO Relay V23162B 548B110
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
GOLD Relay SAP4880A
CSK Linear Guideway LMG15LC
Recent related posts
-
07/18/2020
Fault analysis and treatment of excessive oil consumption of the refrigeration compressor of piston chiller
Commonly used chillers are divided into piston type, screw type, centrifugal type, and vortex type chiller according to the type of refrigeration compressor used. Their evaporators and condensers generally use shell and tube heat exchangers, the throttling device uses thermal expansion valves, the refrigerant is freon
-
06/13/2020
Global Compressor Duty Motors Market 2020-2026 ABB, Mitsubishi, Toshiba, Siemens,
Global Compressor Duty Motors Market 2020-2026 ABB, Mitsubishi, Toshiba, Siemens ......Global first-tier brand compressor trading platform in okmarts.com
-
04/02/2024
Top Ten Industrial Robot Manufacturers Worldwide
The following are the top ten industrial robot manufacturers in the world, as well as their advantages, disadvantages and market share
-
06/23/2022
What is an Encoder?
An encoder is a communication device that controls the motion of an operating device. Encoders can help determine the speed or position of a motor, or other moving equipment.
-
06/13/2020
Solar driven adsorption refrigeration
Solar driven adsorption refrigeration Shanghai Jiaotong University Wang Ruzhu and other nearly 20 years of painstaking research "adsorption refrigeration adsorption mechanism, cycle construction and thermal design theory" won the second prize of the 2014 ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
01/12/2023
What is a 3/2 Solenoid Valve?
A solenoid valve is an electro-mechanical valve that is commonly employed to control the flow of liquid or gas.
-
03/05/2024
Servo Motor Heat Dissipation: Overheating Reasons and Solutions
Servo motor overheating has always been a headache and is an important factor causing motor shutdown and not to work consistently. How to solve the overheating problem of servo motors should start with source analysis.
-
01/09/2023
5 Refrigeration Solenoid Valve Failures and the Solutions
Refrigeration solenoid valve is an industrial equipment controlled by solenoid. It adjusts mass direction, flow, speed and other parameters in industrial control systems.
-
06/13/2020
Refrigeration compressor installation conditions and precautions
The selection of the installation site is ignored by the staff. Often the compressor will be found at random after it is purchased and used immediately after piping.