Postage for Copeland Compressor CF09K6E-TF5-247
People who bought this item also viewed
ceshitesttest
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Phoenix PLC PLC-OSC-24DC
Swagelok Ball Valve SS-65TSW16T
Balluff Switch BOS 23K-PA-LE10-S4
FULOS Air Cylinder SILB160-500
OMRON Power Supply S8VM-15024P
Recent related posts
-
06/13/2020
Refrigerating oil replacement operation method
Refrigerating oil replacement operation method One. Replacing the freezing oil without internal cleaning: The compressor performs the pumping action, recovers the system refrigerant to the condenser side (note that the minimum suction pressure of the 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ӗ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
07/29/2020
Nine refrigerant leakage locations and solutions
There are many welds on the left and right sides of the evaporator, and there may be more leaks. The leak of the newly installed air conditioner is mainly due to the poor welding skills of the employees of the air conditioner manufacturer.
-
12/13/2023
Comprehensive Guide to 32 Various Refrigerants (Summary of Characteristics& Uses of Commonly Used Refrigerants)
0HFC Series Refrigerants: R134a, R410A, R407C, R417A, R404A, R507, R23, R508A, R508B, R152a
-
12/11/2022
How to Deal with the Abnormal Noises from the Linear Guideways?
The rolling element on the slider of the linear guideway moving back and forth inside the track groove will produce noise, which is a normal phenomenon.
-
07/31/2020
The weather is getting colder and you need to pay attention to these hidden dangers when using air conditioners!
Soon after the summer ends, it feels like a direct transition to winter. The weather began to cool down, and many families began to use air-conditioning and other heating equipment one after another.
-
08/13/2020
Correct operation method and precautions of distribution box during cold storage installation
In the process of cold storage installation, the use of cold storage power distribution boxes is a very important content, but most people are not very familiar with the normal operation of cold storage power distribution boxes.
-
06/13/2020
Do summer air-conditioning rooms need air purifiers
Do summer air-conditioning rooms need air purifiers It is high temperature in summer again. Many people have disputes about whether an air purifier is needed in summer.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
10/12/2023
How Long Does It Take to Make Ice Cubes? Answers to All Your Ice-Making Questions
Ice cubes are a convenient way to keep drinks cold, especially during the hot summer months. They are also used in cocktails, smoothies, and many other recipes. However, have you ever wondered how long it takes to make ice cubes?
-
07/14/2020
What to do if the refrigerator doesn't cool
What to do if the refrigerator doesn't cool Refrigerator freezes but does not refrigerate means that the refrigerator should not freeze inside, but it freezes inside. And the cooling effect is poor and the power consumption is increased. Today PChouse and everyone will take a look at what to do when the refrigerator freezes and how to deal with the refrigerator not cooling.