Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 2.5 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 1.8...2.5 A |
Suitable for induction motors with P | 0.75 kW |
Instantaneous overcurrent releases | 33 A |
Short-circuit breaking capacity | 100 kA |
Weight approx. | 0.298 kg |
Circuit breaker size S00 for motor protection, CLASS 10 A-release1.8...2.5 A
N-release 33 A Screw terminal Standard switchingcapacity with transverse auxiliary switch 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 1.8 - 2.5
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value2.5A
operating current
at AC-3 at 400 V rated value 2.5 A
operating power at AC-3
at 230 V rated value 370 W
at 400 V rated value750 W
at 500 V rated value110 W
at 690 V rated value1500 W
operating frequency at AC-3 maximum 15 1/h
design of the auxiliary switcht ransverse
number of NC contacts for auxiliary contact 1 note 1
number of NO contacts for auxiliary contacts 1 note 1
number of CO contacts for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 2 A at 110 V 2 A at 120 V 2 A at 125 V 2 A at 230 V 0.5 A
operating current of auxiliary contacts at DC-13
at 24 V 1 A at 60 V 0.15 A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 2 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 2 kA
response value current
of instantaneous short-circuit trip unit 33 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value2.5A
at 600 V rated value2.5 A
yielded mechanical performance hp
for single-phase AC motor
at 230 V rated value 0.166 hp
for three-phase AC motor
at 200/208 V rated value 0.5 hp
at 220/230 V rated value 0.5 hp
at 460/480 V rated value 1 hp
at 575/600 V rated value1.5 hp
contact rating of auxiliary contacts according to UL C300 R300
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switchrequired
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit currentIk less 400 A)
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 35 A
at 500 V gL/gG 25 A
at 690 V gL/gG 25 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Siemens Circuit Breaker 3RV1011-1CA15
People who bought this item also viewed
Siemens Circuit Breaker 3RV1011-1BA10
Siemens Circuit Breaker 3RV1011-0BA10
Siemens Circuit Breaker 3RV2011-1DA20
Siemens Circuit Breaker 3RV1021-0EA10
Siemens Circuit Breaker 3WN6261-0FB58-0AK1
Siemens Circuit Breaker 5SY6310-7CC
TRIAD Transformer VPT30-3330
HITACHI Contactor H35-GE
Ferraz Shawmut Fuse BS17GB69V32P
REXROTH Relay HED8OA2X/50K14S
EPCOS Resistor B57364S109L2
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Eaton Contactor DILER-22-G-C
HAWKER Battery 6PzB390
Parker Servo Drive CPX2500S/F8
Recent related posts
-
10/24/2023
How Do Window AC Units Work: Basics, Working Principle, Installation and Maintenance
Window air conditioning units are popular choices for cooling individual rooms or small spaces. Understanding how these units work can help you make informed decisions about their installation and maintenance.
-
08/20/2020
Trouble phenomenon the air conditioner is not cooling, the outdoor unit starts and stops frequently
When the air conditioner is frequently used in summer, many friends will encounter this problem, that is, the outdoor unit of the air conditioner frequently starts and stops, but the indoor unit is not cooled.
-
04/24/2024
FANUC Servo Amplifier Alarm Codes and Solutions (SV460~SV494)
FANUC Servo Amplifier Alarm Codes and Troubleshooting Methods
-
07/18/2022
How to Install the Gear Pump
Before installing the gear pump, please check whether the pump and motor are damaged during transportation, or dirt enters the pump cavity due to the loss and rupture of the dust cover.
-
02/03/2023
6 Types of Commonly Used Gear Reducers
Gear reducers are generally used for transmission equipment with low speed and high torque. The ratio of the numbers of teeth of the big and small gears equals the transmission ratio.
-
11/12/2021
Basics of Industrial Control System and the Use of PLC
The components of industrial control system (ICS) can be roughly divided into two categories according to their location: control center equipment and remote site equipment.
-
06/23/2022
How to Install a HMI and 4 Common Failures?
In nearly any assembly line, or manufacturing plant, employees work with touchscreens every day.
-
07/09/2020
Air Compressor Market in APAC – Industry Analysis and Growth Forecast to 2024
Asia Air Compressor Market ASEAN air compressor market size is expected to reach $1.13 billion by 2024, registering a CAGR of 3.6% during the forecast period. The major factors stimulating the market growth includes growing automotive industry and increasing investments in construction industry in the region.
-
09/08/2020
21 problems that should be paid attention to when using air compressor inverter
Improper use of the inverter will not only fail to give full play to its excellent functions, but may also damage the inverter and its equipment, or cause interference, etc. Therefore, the following matters should be noted during use:
-
09/07/2020
Principle and function of temperature control valve of screw air compressor
Each component of the screw air compressor has its unique and important role, such as air filter, oil filter, safety valve, temperature control valve, one-way valve, etc. If one of them is missing, the screw air compressor will not function properly.