Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 3.2 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 2.2...3.2 A |
Suitable for induction motors with P | 1.1 kW |
Instantaneous overcurrent releases | 42 A |
Short-circuit breaking capacity | 100 kA |
Weight approx. | 0.299 kg |
Circuit breaker size S00 for motor protection, CLASS 10 A-release2.2...3.2 A
N release 42 A 1 NO+1 NC transverse Screw terminalStandard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 2.2 - 3.2
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value3.2A
operating current
at AC-3 at 400 V rated value 3.2 A
operating power at AC-3
at 230 V rated value 550 W
at 400 V rated value1100 W
at 500 V rated value1500 W
at 690 V rated value2200 W
operating frequency at AC-3 maximum 15 1/h
design of the auxiliary switcht ransverse
number of NC contacts for auxiliary contact 1 note 1
number of NO contacts for auxiliary contacts 1 note 1
number of CO contacts for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 2 A at 110 V 2 A at 120 V 2 A at 125 V 2 A at 230 V 0.5 A
operating current of auxiliary contacts at DC-13
at 24 V 1 A at 60 V 0.15 A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 3kA
at 690 V rated value 2 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 3 kA
at AC at 690 V rated value 2 kA
response value current
of instantaneous short-circuit trip unit 21 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value3.2A
at 600 V rated value3.2 A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 0.1 hp
at 230 V rated value 0.25 hp
for three-phase AC motor
at 200/208 V rated value 0.5 hp
at 220/230 V rated value 0.75 hp
at 460/480 V rated value 1.5 hp
at 575/600 V rated value 2 hp
contact rating of auxiliary contacts according to UL C300 R300
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switchrequired
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit currentIk less 400 A)
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 40 A
at 500 V gL/gG 35 A
at 690 V gL/gG 35 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Siemens Circuit Breaker 3RV1011-1DA15
People who bought this item also viewed
Fuji Circuit Breaker EW100EAG-3P063
Siemens Circuit Breaker 3RV1021-0KA10
Siemens Circuit Breaker 3RV1021-1BA10
Siemens Circuit Breaker 5SY4325-7
Schneider Circuit Breaker LV510337
Siemens Circuit Breaker 5SY5263-7CC
Terasaki Circuit Breaker XS225NS
Siemens Circuit Breaker 3RV1031-4GA10
TRIAD Transformer FP20-300
Siemens Contactor 3RT2016-2KB42
Littelfuse Fuse 0473007.YRT1L
HONGFA Relay HF32FA-G-005-HS2
UniOhm Resistor 1206W4J0101T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SMC Sensor PFM711S-02-C
FLUKE Pressure Gauge 2700G
SMC Solenoid Valve VQ4100Y-51
GOODSKY Relay GZR-S-112L
Festo Air Cylinder SLG-12-500-YSR-A
Recent related posts
-
09/28/2022
What is a Hydraulic Vane Pump?
With the development of hydraulic technology, vane pump, as an indispensable power element, has been more and more deeply penetrated into various fields such as hydraulic systems
-
07/10/2020
Hitachi compressor features:
Hitachi compressor features: 1. Whether Hitachi compressors use refrigerant R22 or the new chlorine-free refrigerants R134a, R404A, R507A and R407C, they can operate smoothly and reliably.
-
01/11/2021
You may have been on this princess cruise ship, but you don’t know that she has made Mitsubishi Heavy Industries
You may have been on this princess cruise ship, but you don’t know that she has made Mitsubishi Heavy Industries Michelin-starred cuisine, 748 luxurious rooms with private terraces, four swimming pools of different sizes, a princess theater that can se 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ི
-
03/16/2023
The Installation and Maintenance of Water Pump
1.Check whether the water pump motor is in good condition. 2.Good airtightness should be ensured between water pump and pipeline.
-
06/20/2020
Scroll compressor structure diagram_Scroll compressor advantages and disadvantages
Scroll compressor structure diagram <img src="{{media url="Scroll_compressor_structure_diagram_Scroll_compressor_advantages_and_disadvantages.jpg"}}" alt="" /> Scroll compressor is a positive displacement compression compressor, the compression component is composed of moving scroll and static scroll. Its working principle is to use the relative orbital motion of the movable and static scrolls to form a continuous change in the enclosed volume, so as to achieve the purpose of compressing gas. Mainly used in air conditioning, refrigeration, general gas compression, and used in automobile engine supercharger and vacuum pump, etc., it can replace traditional medium and small reciprocating compressors in a large range. <img src="{{media url="Scroll_compressor_structure_diagram_Scroll_compressor_advantages_and_disadvantages2.jpg"}}" alt="" />
-
03/06/2024
Intake vs. Exhaust Fans: Understanding Their Roles, Differences & Applications
In the realm of ventilation and climate control, the roles of intake and exhaust fans are pivotal.
-
09/27/2023
Industrial Water Chiller Repair: Troubleshooting and Maintenance Tips
An industrial water chiller is a critical component in many manufacturing and industrial processes. It is responsible for cooling various types of equipment, which helps to prevent overheating and maintain optimal performance.
-
07/27/2020
ABB inverter fault codes and solutions
After an ABB inverter fails, many people don't know what to do, and they look for experts everywhere for advice. In fact, many times, just check the inverter's fault code to know what specific fault has occurred in the inverter, and you can prescribe the right medicine
-
06/14/2020
Screw compressor overhaul
Screw compressor overhaul Screw compressor overhaul, normal working condition of refrigeration system in operation: 1. The suction temperature of the compressor should be 5-15 ℃ higher than the evaporation temperature; 2. The discharge temperature 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱
-
08/31/2022
Top 3 Things you must Know about Circuit Breaker
The circuit breaker is a very common safety component in the circuit. It can break the circuit at the proper time to protect the circuit and other equipment. To better learn about how it works, we’d better figure out some key concepts.