| Type | 3RV1 |
| Breaker Type | Motor Protection Circuit Breakers |
| Rated current | 20 |
| Number of Poles | 1 pole |
| Setting range for thermal overload releases | 14...20 A |
| Suitable for induction motors with P | 7.5 kW |
| Instantaneous overcurrent releases | 260 A |
| Short-circuit breaking capacity | 50 kA |
| Weight approx. | 1.071 kg |
Circuit breaker size S2 for motor protection, Class 20 A-release
14...20 A Short-circuit release 260 A Screw terminal Standard
switching capacity !!! Phased-out product !!! Successor is SIRIUS
3RV2 Preferred successor type is 3RV2031-4BB10
product brand name SIRIUS
product designation circuit breaker
design of the product for motor protection
General technical data
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 14.5 W
at AC in hot operating state per pole 4.8 W
surge voltage resistance rated value 6 000 V
protection class IP
on the front IP20
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 50 000
continuous current rated value 20 A
Ambient conditions
installation altitude at height above sea level
maximum
2 000 m
ambient temperature
during operation -20 ... +60 degrees centigrade
during storage -50 ... +80 degrees centigrade
during transport -50 ... +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent
overload release
14 - 20 A
operating voltage
rated value 690 V
at AC-3 rated value maximum 690 V
operating current
at AC-3
at 400 V rated value 20 A
operating power
at AC-3
at 400 V rated value 7.5 kW
operating frequency
at AC-3 maximum 15 1/h
Auxiliary circuit
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class Class 20
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 50 kA
at AC at 500 V rated value 12 kA
at AC at 690 V rated value 5 kA
Short-circuit protection
design of the overcurrent release and short-circuit
release
thermomagnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 50022
height 140 mm
width 55 mm
depth 149 mm
required spacing with side-by-side mounting
backwards 0 mm
at the side 0 mm
Connections/ Terminals
product function
removable terminal for auxiliary and control
circuit
No
type of electrical connection
for main current circuit screw-type terminals with box terminals
for auxiliary and control circuit screw-type terminals
arrangement of electrical connectors for main current
circuit
front side
type of connectable conductor cross-sections
for main contacts
solid 2x (0.75-16 mmsquare)
stranded 2x (0.75 - 25 mmsquare), 1x (0.75 -35 mmsquare)
finely stranded with core end processing 2x (0.75 - 16 mmsquare), 0.75-25 mmsquare
at AWG conductors for main contacts 2x (18 -2), 1x (18 -2)
Ask questions
(0/1,200)
- Q: Can I change the shipping address after placing an order?
A: We understand that sometimes you may need to change the shipping address. Please contact our customer service as soon as possible, and we will do our best to accommodate your request, depending on the order status and feasibility.
- Q: Is my personal information secure when shopping on your platform?
A: Absolutely! We take the security and privacy of your personal information seriously. Our platform utilizes advanced encryption and security measures to protect your data, ensuring a safe and secure shopping experience.
- Q: Are there any restrictions on using multiple discount codes for a single order?
A: The use of multiple discount codes for a single order may be subject to certain restrictions. Please refer to the terms and conditions of the discount codes or contact our customer service team for more information.
Reviews
- L
Linore Maugeri
Mar 28, 2025
Siemens Circuit Breaker 3RV1031-4BB10I got exactly what I ordered, and it arrived right on time.HelpfulUnhelpful - T
Tyler Collins
Mar 21, 2025
Siemens Circuit Breaker 3RV1031-4BB10We'll get your order shipped out to you in the next few days.HelpfulUnhelpful - L
Luis Salazar
Sep 10, 2024
Siemens Circuit Breaker 3RV1031-4BB10We shipped the items out with a smile.HelpfulUnhelpful - M
Modesto Colon
Apr 29, 2024
Siemens Circuit Breaker 3RV1031-4BB10Received order in a timely manner. Thanks.HelpfulUnhelpful - A
Anonymous user
Nov 25, 2022
Siemens Circuit Breaker 3RV1031-4BB10All was ok! No problems whatsoever.HelpfulUnhelpful
Siemens Circuit Breaker 3RV1031-4BB10
✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
People who bought this item also viewed
Siemens Circuit Breaker 3WT8040-7UG04-5AB1
Siemens Circuit Breaker 3WT8080-6UG04-5AB1
Siemens Circuit Breaker 3WT8080-4UG04-5AB1
AEG Circuit Breaker EP63ULC32
Delixi Transformer JBK-400VA
HITACHI Contactor H250-G
Fuji Fuse CR2L-75/UL
SIEMENS Relay 3UG4633-1AL30
UniOhm Resistor 201007J0395T4E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
ROTEN Mechanical Seal 2-16-X
Kompass Vane Pump T6EC-042-005-1R00-B1
NEW-ERA Air Cylinder PPT-GT6Y-5-TPQR-RC52LA
Keyence Servo Motor MV-B40K
AirTAC Air Cylinder MAD40X250S
Festo Air Cylinder DGC-K-25-1350-PPV-A-GK
YORK Sensor 035G00037-035
CKD Air Cylinder SCPG2-L-CB-6-35
Copeland Compressor ZPD182KCE-TFD-455