| Type | 3RV2 |
| Breaker Type | Motor Protection Circuit Breakers |
| Rated current | 0.63 |
| Number of Poles | 1 pole |
| Setting range for thermal overload releases | 0.45...0.63 A |
Circuit breaker size S00 for motor protection, CLASS 10 A-release
0.45...0.63 A N-release 8.2 A screw terminal Standard switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at AC
rated value
690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400 V
in networks with grounded star point between
main and auxiliary circuit
400 V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles)
typical 100 000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2 000 m
ambient temperature
during operation -20 ... +60 degrees centigrade
during storage -50 ... +80 degrees centigrade
during transport -50 ... +80 degrees centigrade
temperature compensation -20 ... +60 degrees centigrade
relative humidity during operation 10 ... 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent
overload release
0.45 ... 0.63 A
operating voltage
rated value 690 V
at AC-3 rated value maximum 690 V
operating frequency rated value 50 ... 60 Hz
operating current rated value 0.63 A
operating current
at AC-3
at 400 V rated value 0.63 A
operating power
at AC-3
at 230 V rated value 90 W
at 400 V rated value 180 W
at 500 V rated value 180 W
at 690 V rated value 250 W
operating frequency
at AC-3 maximum 15 1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
number of CO contacts
for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 2 A
at 120 V 0.5 A
at 125 V 0.5 A
at 230 V 0.5 A
operating current of auxiliary contacts at DC-13
at 24 V 1 A
at 60 V 0.15 A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 8.2 A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.63 A at 600 V rated value 0.63 A
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit
current Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 690 V gL/gG 6 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97 mm
width 45 mm
depth 97 mm
required spacing
for grounded parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for grounded parts at 500 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 500 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for grounded parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm
for live parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm
Connections/ Terminals
product function
removable terminal for auxiliary and control
circuit
No
type of electrical connection
for main current circuit screw-type terminals
for auxiliary and control circuit screw-type terminals
arrangement of electrical connectors for main current
circuit
Top and bottom
type of connectable conductor cross-sections
for main contacts
single or multi-stranded 2x (0,75 ... 2,5 mm?), 2x 4 mm?
finely stranded with core end processing 2x (0.5 ... 1.5 mm?), 2x (0.75 ... 2.5 mm?)
at AWG conductors for main contacts 2x (18 ... 14), 2x 12
type of connectable conductor cross-sections
for auxiliary contacts
single or multi-stranded 2x (0,5 ... 1,5 mm?), 2x (0,75 ... 2,5 mm?)
finely stranded with core end processing 2x (0.5 ... 1.5 mm?), 2x (0.75 ... 2.5 mm?)
type of connectable conductor cross-sections at
AWG conductors for auxiliary contacts
2x (20 ... 16), 2x (18 ... 14)
tightening torque
for main contacts with screw-type terminals 0.8 ... 1.2 N.m
for auxiliary contacts with screw-type terminals 0.8 ... 1.2 N.m
design of screwdriver shaft Diameter 5 to 6 mm
size of the screwdriver tip Pozidriv 2
design of the thread of the connection screw
for main contacts M3
of the auxiliary and control contacts M3
Safety related data
B10 value
with high demand rate acc. to SN 31920 5 000
proportion of dangerous failures
with low demand rate acc. to SN 31920 50 %
with high demand rate acc. to SN 31920 50 %
failure rate FIT
with low demand rate acc. to SN 31920 50 FIT
T1 value for proof test interval or service life acc. to
IEC 61508
10 y
display version
for switching status Handle
Ask questions
(0/1,200)
- Q: Can I place an order over the phone?
A: Yes, in some cases, you may be able to place an order over the phone. Please contact our customer service team and provide them with the necessary details to assist you with the phone order process.
- Q: How can I compare prices and reviews of similar products?
A: On the product list page, you can view the prices and ratings of different items simultaneously. You can also use filters to sort products by price or rating, facilitating your comparison and selection.
- Q: Can I place an order for an out-of-stock item?
A: If an item is currently out of stock, you may not be able to place an order for it. However, you can sign up for a notification to be informed when the item is back in stock.
Reviews
- J
Joseph Witzmann
Aug 22, 2025
Siemens Circuit Breaker 3RV2011-0GA15Product arrived quickly, all good.HelpfulUnhelpful - T
Tim Collins
May 06, 2025
Siemens Circuit Breaker 3RV2011-0GA15Exactly as I liked it.HelpfulUnhelpful - D
David Harrison
Apr 04, 2025
Siemens Circuit Breaker 3RV2011-0GA15The website is really easy to use and navigate.HelpfulUnhelpful - D
Derius Page
May 05, 2024
Siemens Circuit Breaker 3RV2011-0GA15Los servicios proporcionados son excelentes..HelpfulUnhelpful - A
Anonymous user
Nov 25, 2022
Siemens Circuit Breaker 3RV2011-0GA15All was ok! No problems whatsoever.HelpfulUnhelpful
Siemens Circuit Breaker 3RV2011-0GA15
✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
People who bought this item also viewed
Siemens Circuit Breaker 3WT8080-7UG04-5AB1
Siemens Circuit Breaker 5SY4301-7CC
Siemens Circuit Breaker 3WL1116-2CB32-4AN2
Siemens Circuit Breaker 3WT8100-7UG00-0AA1
Siemens Circuit Breaker 5SY4608-8CC
Siemens Circuit Breaker 3RV5041-4KA10
ABB Circuit Breaker GSN201 L AC-C6/0.03
TRIAD Transformer F28-040
Siemens Contactor 3RT2325-2AF00
DEHN Surge Protection Device DSH TT 255
Ferraz Shawmut Fuse PC33UD69V1250A
TOWARD Relay AC38S
UniOhm Resistor 0805W8J011JT5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
YUKEN Vane Pump S-PV2R2-26-F-RAA-45
Yaskawa Servo Motor SGMMG-20ADC6C
TAKEX Sensor F10BPN
LYC Bearing 24052CAK/W33
Schneider Sensor XS118BLPAM12
Fuji VFD Frequency Converter FRNF50C1S-6A11
Yaskawa Servo Motor SGMJV-04A3A6S