✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
| Type | 3RV2 |
| Breaker Type | Motor Protection Circuit Breakers |
| Rated current | 73 |
| Number of Poles | 1 pole |
| Setting range for thermal overload releases | 62...73 A |
Circuit breaker size S2 for motor protection, CLASS 10 A-release
62...73 A N-release 949 A screw terminal Standard switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 29.5?W
at AC in hot operating state per pole 9.8?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 20?000
of auxiliary contacts typical 20?000
electrical endurance (switching cycles)
typical 20?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
62?...?73?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 73?A
operating current
at AC-3
at 400 V rated value 73?A
operating power
at AC-3
at 230 V rated value 22?000?W
at 400 V rated value 37?000?W
at 500 V rated value 45?000?W
at 690 V rated value 55?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 65?kA
at 400 V rated value 30?kA
at 500 V rated value 5?kA
at 690 V rated value 2?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 65?kA
at AC at 400 V rated value 65?kA
at AC at 500 V rated value 8?kA
at AC at 690 V rated value 4?kA
response value current
of instantaneous short-circuit trip unit 949?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 65?A
at 600 V rated value 62?A
yielded mechanical performance hp
for three-phase AC motor
at 200/208 V rated value 20?hp
at 220/230 V rated value 25?hp
at 460/480 V rated value 50?hp
at 575/600 V rated value 60?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 160
at 500 V 125
at 690 V 100
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Ask questions
(0/1,200)
- Q: Can I request a specific delivery date for my order?
A: While we strive to deliver orders promptly, specific delivery date requests may not always be possible due to logistics and carrier limitations. However, if you have a specific requirement or need expedited shipping, please contact our customer service, and we will do our best to assist you.
- Q: What should I do if I forgot my password?
A: If you forgot your password, click on the "Forgot Password" link on the login page. Follow the instructions to reset your password.
- Q: Do you offer free shipping?
A: We may offer free shipping on select products or as part of promotional campaigns. You can check the product details or promotions to see if free shipping is available.
Reviews
- P
Phillip Calamia
Jan 26, 2025
Siemens Circuit Breaker 3RV2031-4KA15Fantastic vendor with lightning-fast shipping.HelpfulUnhelpful - B
Buffy Diefenbach
Sep 27, 2024
Siemens Circuit Breaker 3RV2031-4KA15Great seller, satisfied with the purchase.HelpfulUnhelpful - E
Eric Plummer
Sep 12, 2024
Siemens Circuit Breaker 3RV2031-4KA15That was great, I'll be back to shop here.HelpfulUnhelpful - A
Alejandro Herrera
Aug 08, 2024
Siemens Circuit Breaker 3RV2031-4KA15ThanksHelpfulUnhelpful - A
Anonymous user
Nov 25, 2022
Siemens Circuit Breaker 3RV2031-4KA15All was ok! No problems whatsoever.HelpfulUnhelpful
Siemens Circuit Breaker 3RV2031-4KA15
✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
People who bought this item also viewed
Siemens Circuit Breaker 5SY4206-7CC
Siemens Circuit Breaker 3VF7211-2BK60-0AC1
Siemens Circuit Breaker 5SY6614-7CC
Siemens Circuit Breaker 3VA9267-0PK13
Siemens Circuit Breaker 5SN3306-1B
Wurth Transformer 750311591
Siemens Contactor 3RT2026-2XJ40-0LA2
DEHN Surge Protection Device DG 1000
Littelfuse Fuse 0251007.NRT1L
HONGFA Relay HF32FA-012-ZS1
UniOhm Resistor 0.5W510R
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
BANDO Belt T5-990-19
KOINO Switch KH-301-2103
Danfoss Expansion Valve 067N5163
Chint Circuit Breaker DZ47-60 C4 4P
Hanbell Compressor LB-200
THK Bearing LMJK 20LUU
NACHI Vane Pump VDC-13A-2A3-2A3-20
AirTAC Air Cylinder SE40X110
SMC Proportional Valve VEF2141-1-06F