Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 40 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 32...40 A |
Circuit breaker size S2 for motor protection, CLASS 10 A-release
28...36 A N-release 520 A screw terminal increased switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 20?W
at AC in hot operating state per pole 6.7?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
28?...?36?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 36?A
operating current
at AC-3
at 400 V rated value 36?A
operating power
at AC-3
at 400 V rated value 18?500?W
at 500 V rated value 22?000?W
at 690 V rated value 30?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 8?kA
at 690 V rated value 4?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 15?kA
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 520?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 36?A
at 600 V rated value 36?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 3?hp
at 230 V rated value 7.5?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 15?hp
at 460/480 V rated value 30?hp
at 575/600 V rated value 40?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 125
at 500 V 100
at 690 V 80
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Siemens Circuit Breaker 3RV2032-4PA15
People who bought this item also viewed
Siemens Circuit Breaker 3RV1011-0AA10
Siemens Circuit Breaker 3RV1011-0EA10
Siemens Circuit Breaker 3RV1031-4FA10
Schneider Circuit Breaker LV430630
Siemens Circuit Breaker 3VA1463-5EE32-0AA0
Fuji Circuit Breaker BB3ASB-010
TRIAD Transformer VPM18-13800
Panasonic Contactor PT403011
CITEL Surge Protection Device DS44-280
Littelfuse Fuse JTD-4-1/2-ID
HONGFA Relay HF7520-005-HTP(283)
UniOhm Resistor 0805W8F120KT5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Johnson Controls Actuator M9210-AGA-3
Nidec Fan V12E12BS2B5-07A021
SHAKO Air Cylinder JQ50B5
Avesta Welding Wire FCW 2205-PW
Panasonic Servo Motor MDMA082S1T
Schneider Sensor XX512A1KAM8
HAZE Battery HZY2-500-2
Recent related posts
-
09/07/2020
The role of the frequency converter on the air compressor
The frequency converter is a very important controller on the air compressor. The use of the frequency converter in the air compressor system is precisely to make the air compressor system
-
09/22/2020
Discussion on the Causes of Rotor Scaling of Natural Gas Compressor
An oilfield company’s compressor station ammonia compression refrigeration device mainly caused the reduction of natural gas processing capacity and increased power consumption; severe fouling would cause
-
07/14/2020
What to do if the refrigerator doesn't cool
What to do if the refrigerator doesn't cool Refrigerator freezes but does not refrigerate means that the refrigerator should not freeze inside, but it freezes inside. And the cooling effect is poor and the power consumption is increased. Today PChouse and everyone will take a look at what to do when the refrigerator freezes and how to deal with the refrigerator not cooling.
-
03/07/2021
AC servo driver wiring precautions
For signal line and encoder input line, please use shielded wire. Wiring length: the length of signal line from NC to AC servo driver is less than 3m, and the length of input line from AC driver to encoder is less than 20m. The ground wire should be thick wire as far as possible. According to the third grounding standard (grounding resistance < 100 Ω), one point grounding method should be adopted to connect the ground wire. If the motor and the machine tool are insulated, the motor should be grounded.
-
06/14/2020
Screw compressor oil system workflow and common faults
Screw compressor oil system workflow and common faults 1. Working process of screw refrigeration unit The working process of screw refrigeration unit can be divided into refrigerant process and oil system process. Friends who are familiar with screw uni 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ـ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
06/14/2020
Leading refrigeration compressor manufacturer company operating worldwide
Leading refrigeration compressor manufacturer company operating worldwide Emerson GMCC Huayi Compressor Yellowstone Dongbei Randa
-
12/13/2021
Get the Insights of Future Trends of HMI from Delta HMI
HMI is the device connects the user and the machinery system. It is the medium of information transfer and exchange between people and machines. Since the first button switch was developed, man-machine interface monitoring system has become an essential part of industrial production.
-
09/06/2020
What kind of bearing cannot continue to be used and needs to be replaced with a new bearing
To determine whether the bearing can be used again, it should be decided according to the bearing damage level, mechanical performance, importance, operating conditions, inspection cycle and other related factors.
-
06/14/2020
Air-conditioning outside machine caught fire early in the morning, the police reminded to pay attention to the age of electrical appliances
Air-conditioning outside machine caught fire early in the morning, the police reminded to pay attention to the age of electrical appliances
-
06/14/2020
Centrifugal compressor
Centrifugal compressor