Circuit breaker VT160 High switching capacity H Icu = 50 kA,
415/440 V AC 3-pole, system protection Thermal-magnetic trip unit,
Ir = 28..40 A, overload prot. Ii = 500 A, short-circuit prot. without
auxiliary release without auxiliary switches FIXED mounted
number of poles 3
continuous current / rated value 40 A
Short circuit
breaking capacity maximum short-circuit current (Icu)
/ at 400 V / rated value
50 000 A
Connections
Type of connection, main circuit nut keeper plate
type of electrical connection / for main current circuit screw-type terminals
Mechanical Design
Type of mounting fixed mounted
Siemens Circuit Breaker 3VT8204-2BA03-0AA0
People who bought this item also viewed
Fuji Circuit Breaker EW100EAG-3P063
Siemens Circuit Breaker 3RV1021-0KA10
Siemens Circuit Breaker 5SV3344-4
Siemens Circuit Breaker 3RV1011-0DA15
Siemens Circuit Breaker 3RV1011-1CA10
Schneider Circuit Breaker LV431640
Siemens Circuit Breaker 3RV1011-0KA10
TRIAD Transformer F-371P
Eaton Contactor DILM38-10N
Raychem Fuse RGEF500 5A
TYCO Relay RT314A05
UniOhm Resistor 0603WAJ0100T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Versa-Matic Diaphragm Pump E5PP5T5T9C
CHINT Switch NM1LE-250S/4300
Festo Air Cylinder DNC-50-100-PPV-A-KP
Recent related posts
-
02/24/2023
The Differences Between Butterfly Valve and Ball Valve
The biggest difference between butterfly valve and ball valve is that the opening and closing part of butterfly valve is a plate, while the ball valve is a ball.
-
04/16/2024
Servo Motor Overheating: Causes and Solutions
Servo motors are used in many industries in our lives. Some common problems and solutions about servo motors are also of great concern to everyone.
-
08/19/2020
How to dehumidify the refrigeration system of industrial refrigerators
The water content in the industrial refrigerator system comes from two aspects. One is that the vacuum is not in place, so that air and water vapor remain in the system. The other is that the
-
06/14/2020
Refrigeration compressor configuration application and precautions
Compressor configuration Generally speaking, semi-hermetic compressors are equipped with: oil filter, oil hole, exhaust with pressure gauge interface, suction cut-off valve, suction filter, sight glass.
-
10/16/2020
What is the price of Copeland compressor
In recent years, many manufacturers have taken a fancy to the Copeland compressor market and started to become Copeland compressor distributors. The refrigeration industry has also increasingly recognized Copeland compressors, and the scope of use has become wider and wider. On the premise of focusing on quality Next, everyone will pay attention to the price of compressors. What about the price of Copeland compressors? Let's take a look.
-
12/24/2022
How do Erbium Doped Fiber Amplifiers Work?
Erbium doped fiber amplifiers are the most widely used optical amplifiers in optical fiber communications.
-
06/14/2020
Maintenance manual of semi-hermetic refrigeration compressor
Maintenance manual of semi-hermetic refrigeration compressor Compressor Maintenance Good maintenance is the basic guarantee for the safe operation of the compressor unit, extended service life and reduced operating costs. To this end, the maintenance of 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ѭ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ
-
06/24/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
06/14/2020
The school is about to start
Is the campus fresh air system necessary? With the improvement of the epidemic situation in various places, schools in various places have gradually begun to "recycle mythical beasts".
-
03/21/2023
The Operation and Maintenance of Vacuum Pump
About 20 minute’s operation should be done in advance before vacuum pump starts to vacuumize assembling unit. And after oil temperature rises, open extraction valve of assembling unit to extract unit.