There is no price at present, you can Request a Quote
Max flow: 200 l/min
Assembly position: any position
Ambient temperature: -30 - 70 celsuis degree
Pmax 350 bar
ATOS Solenoid Valve AGAM-10/10/50/V
There is no price at present, you can Request a Quote
People who bought this item also viewed
WINMOST Solenoid Valve WD-G03-B2A-A2-N
AirTac Solenoid Valve 5V110-06
KOGANEI Solenoid Valve ME60-M-S3
Toshiba Compressor PH295X2C-8FTC1
Meas Transmitter M5156-000005-016BG
CHINT Transformer JBK1-100
KOMPASS Check Valve MCP-02-A
CAT Overflow Valve CAT306E
Rexroth Piston Pump A4VSO355DRG/22L-PPB13N00
HENGYI Vane Pump VCM-SF-40C-20
Danfoss Sight Glass SG12N
TORCH Capacitor 50V 390PF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder HLQL16X125S
KCL Vane Pump KT6EM-052-2R00
Recent related posts
-
05/20/2022
5 Common Faults and Solutions of Air Cylinders?
Cause 1: The guide sleeve, rod seal ring or piston rod are worn. Solution 1: Replace it. Improve lubrication. Use guide rails.
-
09/04/2021
Where is the Throttle Position Sensor Located?
The throttle Position Sensor (TPS), located on the butterfly spindle, is operated by the throttle, and its installation varies according to the structure.
-
08/08/2022
What is Synchronous Motor
Synchronous motors like induction motors (i.e. asynchronous motors), are a common type of AC motor.
-
06/13/2020
Frequently asked questions about refrigeration compressors Do you know these?
1. Why control the impurity content and moisture content of the compressor and air conditioning system?
-
08/08/2020
Daily maintenance method of precision air conditioner for computer room
With the development of science and technology, the precision air conditioners in the computer room are gradually upgraded, and the cost is getting higher and higher. Therefore, it is more necessary to increase maintenance efforts.
-
01/14/2021
Do you know these 10 questions about air conditioning?
Fluorine deficiency: If the air conditioner in your home is an old-fashioned air conditioner that has been used for a long time, it may be because the Freon refrigerant in the air conditioner is gone, and you can continue to use it only by adding Freon. 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧֖ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
08/14/2020
Low-voltage alarm and fault repair methods for precision air conditioners in computer rooms
The low-pressure alarm for the special air conditioner in the data center computer room is a problem we often encounter in daily maintenance. Especially often encountered in winter.
-
09/10/2020
What problems should be paid attention to when operating the centrifugal oxygen compressor
Compared with air compressors, centrifugal oxygen compressors are characterized by their different working media. Oxygen is a strong oxidizer and combustion-supporting agent. Therefore, there are stricter requirements for safety in design, manufacturing, installation, and use management. E.g:
-
06/27/2022
Introduction to Priming in Pumps
Priming a piston pump is probably the first and one of the most important thing one should do before operating it. Not priming a pump or not doing it properly makes majority of pump problems.
-
07/17/2020
The effect of insufficient refrigerant charge on the chiller
1. If the suction pressure and discharge pressure of the compressor are lower than the normal value, then you need to check to see if it is due to insufficient refrigerant charge.