Fan Type | DC Fan |
Series | M Series |
Voltage | 12 VDC |
Frame Size | 60 mm |
Frame Thickness | 25 mm |
Frame Material | - |
Bearing Type | Vapo |
Speed | Low |
Function | AutoRestart |
Size | 60 mm x 60 mm x 25 mm |
Power Current | 44 mA |
Power Consumption (WATTS) | 0.53 W |
Speed | 3100 RPM |
Air Flow | 16 CFM |
Static Pressure | 0.1 in H2O |
Noise | 16.7dB(A) |
Termination | - |
IP Rating | - |
Approval Agency | - |
Operating Temperature | - |
Weight | - |
We can also provide the following models
EE50102S3-10000-Q99
PMB1204PGB3-AY
GB1208ALV4-AY
SP109WR2082XBT.GN
PMB2407POB1-A
PMB4803AQV4-AY
PMB2404AGVX-A
EE80151V2-0000-H99
PMB0512ABVX-A
PMD4803AQB3-A
PMB2455PTBX-A
MF50101S2-0000-S99
PMB1255PYB3-AY
SP101A1082HSL.GN
MF30154B3-10000-F99
PMD0545PGB4-A
EE40201S3-10000-C99
DP201AT 1122HBL.GN
GB2412AFV3-A
MF50102V2-0000-G99
PMD4808ADV4-A
PF92250B4-10000-S99
PMD1297POBX-A
HAC0251B4-10000-G99
PMB1255AGVX-A
PMD0575AYV1-A
HA30104B2-10000-S99
PE60250S2-10000-C99
PMD2402PLB2-A
PMB0555AGV1-AY
MF17084S3-10000-999
GB0504ALV2-AY
GB1208PEV4-A
PMB0545ANV2-AY
GB2409PNV1-AY
PMB2455PGB1-AY
GB1297ALB2-AY
PMB2405AFVX-A
PMD4855AFVX-A
ME80152S2-10000-C99
EF40204B2-10000-S99
GB0555PPV4-A
EE60200S1-0000-H99
PMB1238AFB3-A
GB2404PFV2-A
PMB2435ABV1-A
PF60561V1-0000-C99
PMB1275ALB4-A
HA40204B4-0000-G99
HA92252S4-10000-Q99
MF60154S1-1B000-A99
For more information,please contact us freely
SUNON Fan MF60251V3-10000-A99
There is no price at present, you can Request a Quote
People who bought this item also viewed
Ebmpapst Fan G2D120-AA22-25
SUNON Fan EG50040V1-C06C-S9A
SUNON Fan B1245PFV1-8A
SUNON Fan AB2123-HBL.GN
SUNON Fan PMD4809PMB1-A
Sanyo Denki Fan 9A0624G402
KAKU Fan KA1238HA2B
SUNON Fan SF23092A 2092HBT.GN
SUNON Fan ME50101V1-000U-G99
COSEL Power Supply NAH-30-332-D
CHINT Transformer JBK1-63
Shilin Contactor S-P40T
TOSHIBA Electric Motor ICF-140-63-2R
LEEMIN Filter LH0240D010BN3HC
EMERSON Sight Glass HMI-STT4
Beckhoff Terminal Box Module IE6012
TYCO Relay 8-1415017-1
BENNIC Capacitor 100V 0.068UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
KUDOM Relay KSJ60D12-L
SMC Solenoid Valve VF5144-5GB-04
YEOSHE Piston Pump PV080PA3RM1A0N
EVERFLOW Fan T127010BU
Beckhoff Module ES3054
Recent related posts
-
08/21/2020
Causes and troubleshooting of industrial chillers
1. High condensing pressure (higher than the specified value) failure causes and remedies: ① Non-condensable gas in the system: release non-condensable gas.
-
06/22/2020
Working principle of steam compressor_steam compressor application
Working principle of steam compressor_steam compressor application Working principle of steam compressor After the steam is filtered by the filter, clean steam then enters the host cavity through the intake valve, and the volume of the cavity changes from large to small to compress the steam. The volume of the cavity is changed by the rotor rotating under the drive of the motor. <img src="{{media url="Working_principle_of_steam_compressor_steam_compressor_application.jpg"}}" alt="" />
-
06/14/2020
Application and design of fresh air system in commercial kitchen equipment
Application and design of fresh air system in commercial kitchen equipment What is the kitchen fresh air system?
-
03/21/2023
The Operation and Maintenance of Vacuum Pump
About 20 minute’s operation should be done in advance before vacuum pump starts to vacuumize assembling unit. And after oil temperature rises, open extraction valve of assembling unit to extract unit.
-
08/09/2020
The meaning of pipe diameter De, DN, d, ф
The meaning of pipe diameter De, DN, d, ф<br></br> The respective ranges of De, DN, d, ф<br></br> De-- PPR, PE pipe, polypropylene pipe outer diameter<br></br>
-
08/25/2020
Renovation of the small turbine of the propylene refrigeration compressor oil station of the DCC unit has achieved initial results
Recently, the technicians of the DCC device have undergone transformation. The temperature of the small turbine bearing box of the propylene compressor oil station of the device has dropped from 90-120 degrees Celsius to 70-85 degrees Celsius
-
01/10/2021
How Air Conditioners Work
Air conditioners use refrigeration to chill indoor air, taking advantage of a remarkable physical law: When a liquid converts to a gas (in a process called phase conversion), it absorbs heat. Air conditioners exploit this feature of phase conversion by fo 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ
-
11/01/2023
Inverter Compressor: Everything You Need to Know
In the world of technology and appliances, constant innovation is a driving force. One such innovation that has significantly impacted the performance and efficiency of electronic devices
-
02/18/2021
How about the cooling effect of the air-conditioning fan
Air-conditioning fans are becoming more and more popular in summer. Of course, the price of air-conditioning fans is cheaper than air-conditioning. Of course, the cooling effect is not comparable to that of air-conditioning. So what about the cooling effect of air-conditioning fans? This is also a problem that everyone is more concerned about. In addition, the principle of the air-conditioning fan is also what you want to know. Let's take a look at the cooling effect of the air-conditioning fan with the editor, for your reference.
-
06/22/2020
What to do if the air conditioner is not cooling
Air conditioning does not refrigerate mainly from the following aspects to solve: 1, regular cleaning and maintenance of air-conditioning outside machine. 2. Replace the old air conditioner that has exceeded the service life. 3. Check whether the copper pipes of the indoor and outdoor units of the air conditioner are too long. 4. Check whether the power of the air conditioner matches the indoor space. 5. Check whether the installation environment of the air conditioner is suitable. 6. Replenish refrigerant. <img src="{{media url="magefan_blog/What_to_do_if_the_air_conditioner_is_not_cooling.jpg"}}" alt="" />