Voltage: three phase
Input: AC 3PH 380-460V 50-60HZ
Output: AC 3PH 0-460V 0-400HZ 3.4A
Rated capacity: 2.6KVA
Yaskawa VFD Frequency Converter CIMR-V7RA40P7
People who bought this item also viewed
Yaskawa VFD Frequency Converter CIMR-F7A4045
Toshiba VFD Frequency Converter VFP7-4220P
Chint VFD Frequency Converter NVF2G-45/TS4
LG LS VFD Frequency Converter SV185iP5A-4NO
Yolico VFD Frequency Converter YD3030-T4A
MitsubishiServo DriveMR-J2-350B
Mitsubishi HMI F940GOT-LBD-H-E
Autonics Rotary Encoder E40H12-40-3-N-24
SIEMENS Actuator GAP196.1E
COSEL Power Supply CBS504805-T
Fuji PLC NC1F-SP2
Minpear Turbine Reducer BWD5-17
CEACENT NIC Card AN860A-T2
TYCO Relay RY533024
FIAMM Battery 12FLB200
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Omron Sensor E2B-M12KN05-M1-B2
Phoenix Function Module IB IL CNT-PAC
BANDO Belt T10-1750-25
OKTY Oil Seal TC(NBR)180*215*15
EVERFLOW Fan F129025BU
Recent related posts
-
07/26/2022
What is A Vane Pump
A vane pump is a self-priming positive displacement pump providing constant flow at varying pressures. Operation is via a motor connected to a gearbox as typically the maximum rpm is 900.
-
06/14/2020
Do you know question and answer with refrigeration compressors?
1. Why control the impurity content and moisture content of the compressor and air conditioning system?
-
01/03/2024
Printer Cooling: Methods, Common Problems & Troubleshooting
Printers are familiar to everyone and are one of the essential office tools for work. From inkjet, dot matrix, laser, to the now popular 3D technology, printers have developed rapidly.
-
08/17/2020
What should I do if the compressor current of an industrial chiller is overloaded? okmarts.com editor has a coup!
The compressor current overload phenomenon of industrial chillers, cause analysis and solutions. The "overcurrent" here refers to the current overload of the chiller compressor.
-
08/05/2020
Basic knowledge of air source heat pump at a glance
1. What is a heat pump?<br></br> Heat pump is not a water pump, or even a pump, but a complete set of equipment. The English name of heat pump, heatpump, has 2 definitions:
-
08/21/2020
Useless for a lifetime. Dehumidification and refrigeration of air conditioners are completely different!
This summer, the heavy rain that has come in New York caught many friends off guard, and the humid and sultry weather made the big guys complain. A small partner told the author that at this time, dehumidification is enough. The air conditioner does not need to be cooled. principle of refrigeration of central air-conditioning chillers
-
06/24/2020
Why the air conditioner does not cool
The cooling load is overloaded or the space is too large, the number of air conditioners is not correct; improper installation will cause poor air circulation, resulting in poor cooling effect; when the freon in the air conditioner is insufficient, it will cause the cooling effect of the air conditioner to deteriorate; the air conditioner is not on time Do cleaning and maintenance, etc.
-
08/19/2020
How to clean air conditioner filter
The use of air conditioners is not unfamiliar to everyone. With the continuous improvement of people’s living standards, air conditioners have been popularized in every family, and the
-
09/06/2020
The difference between variable frequency air compressor and industrial frequency air compressor
The difference between variable frequency air compressor and industrial frequency air compressor: 1. The pressure is stable:
-
04/23/2024
FANUC Servo Amplifier Alarm Codes and Solutions (SV430~SV449)
FANUC Servo Amplifier Alarm Codes and Troubleshooting Methods