Type | Rotary Servo Motors |
Series | SGMG Series |
Rated Output | 7.5 kW |
Voltage | 200 V |
Serial Encoder | 8192 PPR Absolute Encoder |
Rotation Speed | 1500 RPM |
Specifications | Straight flange-type |
Options | Without brakes |
Time Rating | Continuous |
Thermal Class | Class F |
Vibration | 15μm or less |
Withstand Voltage | 1500VAC 1 min |
Insulation Resistance | 500VDC, 10MΩ minimum |
Enclosure | Totally enclosed, self-cooled, IP67 |
Ambient Temperature | 0 to 40ºC |
Ambient Humidity | 20 to 80% (non-condensing) |
Excitation | Permanent magnet |
Drive Method | Direct drive |
Mounting | Flange-mounted |
Yaskawa Servo Motor SGMG-75AWAA
People who bought this item also viewed
Panasonic Servo Motor MFA010LDMNSA
Yaskawa Servo Motor SGMAV-A5ADA21
Yaskawa Servo Motor SGM7G-09AFC61
Yaskawa Servo Motor SGME-08AF12
Yaskawa Servo Motor SGMP-15A3TE11
Yaskawa Servo Motor SGMRV-05ANA-YR11
Panasonic Servo Motor MDMF302L1G6M
Panasonic Servo Motor MSMD022G1A
Delta Servo Motor ECMA-EA1310RS
YUKEN Servo Valve SVD-F11-19-7.5-21
Honeywell Actuator M9164C1001
EMERSON Power Supply R48-3200
Panasonic PLC FPO-SL1
MITSUBISHI Spindle Amplifier MDS-B-SPJ2-075
HAWKER Battery NPGEL90-12
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
MINDMAN Air Cylinder MCJQ-12-40-15M
CRYDOM Relay A2425G
Honeywell Solenoid Valve VE4010A1163
YSC Solenoid Valve YSVF5220-4D
Recent related posts
-
07/04/2020
High Pressure Hydrogen Compressors Market Trends Analysis, Top Manufacturers, Shares, Growth Opportunities, Statistics & Forecast to 2026 | ARIEL, Atlas Copco, Burckhardt
The dramatic spread of COVID-19 has created a marginal impact on the global air compressor market. The sustainability of the air compressor market is mainly attributed to the significantly increasing demand from various industries such as oil & gas, healthcare, chemical manufacturing, and many others.
-
01/11/2021
About Mitsubishi Electric (Guangzhou)
About Mitsubishi Electric (Guangzhou) Mitsubishi Electric (Guangzhou) Compressor Co., Ltd. (abbreviated as MGC) is a wholly-owned Japanese enterprise jointly established by Mitsubishi Electric Corporation, Mitsubishi Electric (China) Co., Ltd. and Mitsub 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ޒ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
06/20/2020
Installation instructions for explosion-proof air conditioners
Installation instructions for explosion-proof air conditioners <img src="{{media url="Installation_instructions_for_explosion-proof_air_conditioners.jpg"}}" alt="" /> 1. The power supply of the explosion-proof air conditioner shall have a dedicated line, and a circuit breaker or air switch shall be provided in the dedicated line. The power supply wires and fuses should comply with the relevant regulations and cannot be changed at will.
-
09/14/2020
Technical standards for silent oil-free air compressors
Technical standard for silent oil-free air compressor 1. Subject content and scope of use 1. This standard specifies the terminology, technical requirements, test methods and inspection rules of silent oil-free air compressors.
-
06/26/2020
Maintenance method of refrigerator compressor without stopping
Maintenance method of refrigerator compressor without stopping The focus of non-stop compressor maintenance is on the cooling effect. If the cooling effect is normal without stopping, the fault is in the thermostat. Otherwise, it is because the system lacks fluorine and the temperature falls below the control point, which results in non-stop. When repairing,
-
06/30/2020
What are the causes of compressor overheating
What are the causes of compressor overheating Some causes of compressor overheating: high return air temperature, large motor heating capacity, high compression ratio, high condensing pressure, and improper refrigerant selection.
-
07/23/2020
Analysis of Overheating Failure of Refrigeration Compressor
The main reasons for the overheating of exhaust temperature are as follows: high return air temperature, large heating capacity of the motor, high compression ratio, high condensation pressure, and improper refrigerant selection.<br></br> <br></br>
-
09/06/2020
What are the advantages and characteristics of power frequency screw air compressors
What are the advantages and characteristics of power frequency screw air compressors? Power frequency screw air compressor adopts high-efficiency host The power frequency screw air compressor adopts the industry-leading screw main engine, high efficiency, low speed, the rotor adopts the third-generation tooth profile
-
05/04/2023
What is Vapour Compression Refrigeration System?
Vapour compression refrigeration system (VCRS) is the most common cooling system used in modern refrigeration technology.
-
10/05/2023
Freeze Drying vs Dehydration: Is a Freeze Dryer and a Dehydrator the Same Thing
When it comes to preserving food, there are a variety of methods that can be used. Two of the most common methods are freeze-drying and dehydrating.