Bore size(mm):32
Temperature:-20...70 degrees Celsius
Cushion type:Bumper
Port size(Note):1/8"
Note:PT thread is available.
AirTAC Air Cylinder TN32X55S
People who bought this item also viewed
CKD Air Cylinder SCPG2-M-00-10-30
KOGANEI Air Cylinder NHBRS-10
CHANTO Air Cylinder DXSL20X15
AirTAC Air Cylinder TCM10X10S
AirTAC Air Cylinder BSE40X350
AirTAC Air Cylinder ACQ12X5S
Festo Air Cylinder DFM-16-100-B-PPV-A-GF
KOGANEI Air Cylinder MGAS10X15-L
MINDMAN Air Cylinder MCQA-11-50-500
Daikin Solenoid Valve KSO-G02-2AA-30-N
Belimo Actuator FSAF230
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Panasonic PLC FPO-E32T
Tecumseh Compressor TAJ2446Z
YOTEC Water Pump WQD15-10-1.1 220V
Ebmpapst Fan W2E250-HL06-10
Recent related posts
-
07/07/2022
Proportional Solenoid Valve - How They Work
A proportional control valve is a valve used to control fluid flow rate by varying the size of the flow passage via a restrictor.
-
06/14/2020
Broken refrigeration compressor bearings? What can be repaired? Which must be thrown?
Broken refrigeration compressor bearings? What can be repaired? Which must be thrown? How to judge whether the bearing can be used again and the defects of the bearing need to be replaced To determine whether the bearing can be used again, it should be 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱
-
06/22/2020
What's wrong with air conditioning and cooling
1.The air conditioner lacks freon. Under such circumstances, the air conditioner cooling effect will be poor. 2. If there is a lot of dust and dirt in the filter, it will affect the heat dissipation effect, which will affect the cooling. 3. The outdoor temperature is too high, and it is difficult to lower the temperature by turning on the air conditioner at home. 4. Voltage problem, the power supply voltage of normal air conditioner is 220V, but if it is lower than 220V, the cooling effect will be greatly affected. Summer is coming soon, and the weather is getting hotter. But if the cooling effect of the air conditioner is not good after turning on, what is going on? Is there any good solution? <img src="{{media url="magefan_blog/What_s_wrong_with_air_conditioning_and_cooling.jpg"}}" alt="" />
-
08/20/2020
Placement of the thermostatic valve bulb
The bulb should be as close as possible to the outlet of the evaporator and placed in close contact with the outlet pipe. In the part of the pipe section where the temperature bulb is in contact with the pipe,
-
06/29/2020
Semi-closed piston refrigeration compressor 4SJH-3000
Semi-closed piston refrigeration compressor 4SJH-3000 Features of semi-hermetic piston compressor 4SJH-3000: 1. Light in size and small in space 2. Suitable for R12, R22 and R502, with a wide range of applications
-
06/14/2020
Give home N95 level protection, home fresh air system, real breathing enjoyment!
Give home N95 level protection, home fresh air system, real breathing enjoyment! After the epidemic, the fresh air system once again refreshed people's understanding.
-
07/28/2020
Common faults and solutions of screw chillers
Low voltage overrun protection:<br></br> Solution: Replace or clean the filter element; clean the suction port filter.<br></br> Dirty or ice blockage at the inlet of the expansion valve:<br></br> Solution: Dirty blockage: remove the expansion valve and clean it. Ice blockage: replace the filter drier and run again
-
09/23/2022
Structural Characteristics of Gear Pump and Its Working Principle
Gear pump is a kind of hydraulic pump widely used in hydraulic systems. It is generally made into a fixed displacement pump.
-
08/17/2020
What are the effects of water quality on water-cooled chillers
If the cooling performance of water-cooled chillers is to be kept in a stable state, very strict requirements on the water source are required. In the daily use of chillers, if the company does not pay enough attention to the quality of the water source
-
09/23/2020
Application of DCS system in anti-surge control system of air separation compressor
Keywords: DCS system, air separation compressor, anti-surge control system Preface The 6000m3/h air separation plant of Xilin Iron and Steel Company was completed in May 2001 by Hangzhou Oxygen Concentrator Group Company. The factory design was designed by Beijing Iron and Steel Design Institute. It was successfully put into operation on September 2, 2001, and it took more than half a year to run. It shows that the unit is operating stably, and all indicators have reached or exceeded the design value. The entire control system uses Honeywell’s TDC3000 and two GUS stations.