There is no price at present, you can Request a Quote
Type | Counter functions modules |
System | X20 System |
Description | X20 digital counter module, 1 ABR incremental encoder, 5 V (single-ended), 250 kHz input frequency, 4x evaluation, encoder monitoring, NetTime function |
B&R ID code | 0xA707 |
Power consumption | 0.01 W |
CE | Yes |
UKCA | Yes |
ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc,IP20, Ta (see X20 user's manual),FTZÚ 09 ATEX 0083X |
UL | cULus E115267,Industrial control equipment |
HazLoc | cCSAus 244665,Process control equipment,for hazardous locations,Class I, Division 2, Groups ABCD, T5 |
DNV | Temperature: B(0 to 55°C),Humidity: B(up to 100%),Vibration: B(4 g),EMC: B(bridge and open deck) |
LR | ENV1 |
KR | Yes |
ABS | Yes |
BV | EC33B,Temperature: 5 - 55°C,Vibration: 4 g,EMC: Bridge and open deck |
EAC | Yes |
KC | Yes |
Nominal voltage | 24 VDC |
Input voltage | 24 VDC -15% / +20% |
Input current at 24 VDC | Approx. 3.3 mA |
Input circuit | Sink |
Connection type | 3-wire connections |
Electrical isolation | Channel isolated from bus,Channel not isolated from channel |
Degree of protection per EN 60529 | IP20 |
Operating temperature | -25 to 60°C |
Operating Relative Humidity | 5 to 95%, non-condensing |
Pitch | 12.5+0.2mm |
B&R Module X20DC1976
There is no price at present, you can Request a Quote
People who bought this item also viewed
B&R Controller Module 3IF050.6
B&R Controller Module 3AM050.6
B&R Controller Module ECPNC8-23
B&R Controller Module X20BC0083
B&R Controller Module 3PS465.9
Kuroda Module A40PW-01U-1Y100
Beckhoff Module EL6751-1006
Beckhoff Module EL7211-0010
Delta Servo Motor ECMA-E1310SS
Bosch Rexroth Servo Drive DDS03.2-W030-B
Renishaw Encoder RGH22S05F61A
Panasonic PLC AFPX-C14RD
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Sanyo Compressor C-SB351H5A
Endress Hauser Transmitter PMC71-ABA1E2GHAAA
DAITO Fuse P420L
Recent related posts
-
01/02/2021
Why Genuine Danfoss?
Watch out for counterfeits to protect your image. There is every reason to make sure that the product you pick up is genuine Danfoss quality. All Danfoss products are built on an impressive platform of know how and experience. The material we use and 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉
-
07/19/2022
Common Types of Diaphragm Pump
An oil-free lubricating pneumatic diaphragm pump belongs to the field of pneumatic machinery.
-
09/14/2020
Analysis of the consequences of refrigerant liquid entering the compressor
When the refrigerant liquid entering the evaporator is too much or the evaporation pressure is too low, the cold The medium liquid will be sucked into the compressor. Since the refrigerant liquid is incompressible,
-
09/05/2020
What are the characteristics of the filter material glass fiber
As the most widely used filter material in current high-efficiency and sub-high-efficiency filters, glass fiber has the following characteristics:
-
09/01/2020
Dr. Zhang Xuefeng, Executive Director of Sigatobo Battery Air Compressor, accepted an exclusive interview with Gaogong Hydrogen!
Gaogong Hydrogen Electric: Established in 2011, Sigatobo has 8 years of product research and development experience and deep market knowledge. What are the core technologies of the company's hydrogen fuel cell air compressor?
-
08/14/2020
Trouble shooting and correct selection method for thermal expansion valve debugging
As we all know, the thermal expansion valve is one of the four major components in the refrigeration system. It is responsible for reducing the refrigerant from the condensing pressure to the evaporating pressure in the system
-
07/13/2020
Danfoss expert analysis! Causes and troubleshooting of compressor start-up with liquid
Identify the authenticity of Danfoss compressors, solenoid valves, expansion valves, and filters Danfoss T2 valve true and false comparison:
-
06/14/2020
What is the effect of pressure and temperature on the refrigeration system
What is the effect of pressure and temperature on the refrigeration system Refrigeration system performance testing involves many aspects, of which pressure and temperature are two points that cannot be bypassed. Today we will take a look at the pressure 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦
-
06/14/2020
How important is the installation environment of the refrigeration unit It is enough to do these 4 points!
How important is the installation environment of the refrigeration unit It is enough to do these 4 points! The refrigeration equipment (compressor unit) is installed in the machine room, and the surrounding environment should be maintained:
-
06/22/2020
Causes and judgement of centrifugal compressor surge
Causes and judgement of centrifugal compressor surge Causes of centrifugal compressor surge ①Flow<img src="{{media url="Causes_and_judgement_of_centrifugal_compressor_surge.jpg"}}" alt="" /> Each centrifugal compressor corresponds to a curve between outlet pressure P and flow rate Q at different speeds n, as shown in Figure 2.