There is no price at present, you can Request a Quote
Body Type | ZB Compressor |
Product Type | Scroll Compressors |
App | HT |
Capacity BTU/HR | 101000 |
EER BTU/WH | 11 |
Freq | 60Hz |
Phase | 3Ph |
Voltage | 208/230 |
Ref | 22 |
Copeland Compressor ZB66KC-TFC-250
There is no price at present, you can Request a Quote
People who bought this item also viewed
Mitsubishi Compressor TNB306FPGMC-L
Sanyo Compressor C-RN113H3C
Tecumseh Compressor TAJ4511A
Toshiba Compressor PA200X2CS-3MUU
Copeland Compressor ZRH116KTE-TFD-502
Copeland Compressor ZP31K5E-PFV-622
Copeland Compressor CRNQ-0300-TFD-522
Copeland Compressor ZR72KC-TF7-522
Samsung Compressor DS-GB052FAVA
GMCC Compressor PH150G1C-4DZDE
Hitachi Compressor E655DH-65D2Y
LG Compressor QJ258KDA
CHINT Transformer SG-150
Parker Sporlan Expansion Valve OVE-30-C
Siemens Contactor 3RT2026-2KB40
Delta Fan AFB0512HD
FANUC Electric Motor A06B-1453-B150
Ingersoll Rand Filter 54509500
EMERSON Sight Glass AMI-1SS3
SAMYOUNG Capacitor 16V 22UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Schneider Circuit Breaker NSC100B4080N
Danfoss Expansion Valve 068U1912
Recent related posts
-
07/04/2020
Five damage situations known to the compressor
Five damage situations known to the compressor Air conditioning has always been an indispensable "good companion" to accompany the hot summer! The reason the air conditioner can bring us cool is because of its internal compressor. If the air conditioner is used more and more frequently, then its internal compressor is prone to malfunction or even damage.
-
08/21/2020
Trouble phenomenon the air conditioner is not cooling, the outdoor unit starts and stops frequently
When the air conditioner is frequently used in summer, many friends will encounter this problem, that is, the outdoor unit of the air conditioner frequently starts and stops, but the indoor unit is not cooled.
-
08/18/2020
How to wire the cold storage distribution box What problems should be paid attention to when wiring
Cold storage power distribution boxes play a very important role in the use of cold storage, and many people do not know much about cold storage power distribution boxes. Let's take a look at it with okmarts.com editor.
-
06/14/2020
15 common sense of refrigeration and air conditioning!
1. The air conditioner cannot be restarted immediately after it is turned off After the central air conditioner is shut down, it can only be operated after 3 minutes. This is because the timing protector will automatically work to prevent the compresso 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ
-
01/19/2024
Central Air Conditioning System: Types, Components, and Brands (including Mitsubishi Electric, Daikin, York, Carrier, etc.) (Part 1)
The various parameters of the central air conditioning system are basically outperformed by various wall-mounted units and cabinet units, but they have incomparable advantages in terms of space and appearance.
-
09/14/2020
Analysis of common failures of air-cooled compressors (1)
There are three common failures in the main components of air-cooled compressors: 1. Failure of the gas circuit system 2. Failure of the oil circuit system 3. Failure of the transmission mechanism. Do some system analysis below
-
03/01/2024
A Guide to Fresh Air Ventilation System: Working Principle, Functions & Types
Fresh air ventilation system, also known as "house breathing system", is a type of indoor exhausting and ventilation system. It can discharge the dirty indoor air to the outside while also pulling fresh outdoor air into the room.
-
07/07/2020
How much do you know about the diameter of the refrigeration system and the return of the upstream pipe
How much do you know about the diameter of the refrigeration system and the return of the upstream pipe When the refrigeration equipment is under low load, if it is found that the oil return cannot be normal, it can be calculated according to the minimum return oil flow rate.
-
07/16/2020
How to see if the refrigerant leaks in the high and low temperature test chamber
How to check whether the refrigerant leaks in the high and low temperature test box; the standard high and low temperature test box and the constant temperature and humidity test box are all selected by the air-cooled compressor, and the working principle is the same as that of the air conditioning refrigeration
-
07/22/2020
The fluorine refrigeration compressor is short of oil, how to add it?
When the compressor is running for a period of time, we can judge whether the compressor is short of oil by observing the oil glass. If the oil level in the oil glass is lower than half of the position, then we need to replenish the oil. This article introduces the oil replenishment method of small and medium-sized compressors.