Supply Voltage: 5-26V
Protection Class: IP54, IP66
Approvals/ Certifications: CE, ROHS
Operating Temperature Range: 0 degrees+70 degrees
Enviroment: Non-Hazardous
This one is the substitute for the originial H231000002035
Dynapar Encoder H231000002035
People who bought this item also viewed
Dynapar Encoder H5820480101X019
LS Mecapion Encoder H40-8-0360ZC
Renishaw Encoder T2001-15A
HONTKO Encoder HSK-1200-2
Mitsubishi Servo Motor HF-H154S
Panasonic Servo Drive MCDKT3520CA1
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SBC Linear Guideway SBG25FL-C-K12OCS
SuperRed Fan CHA4012CS
BRAHMA Solenoid Valve EG25*SR.3*SRD*GMO
Nedfon Fan KTJ(D)-28-26
Toshiba VFD Frequency Converter VFS7-4007UPL
Recent related posts
-
12/28/2022
Classifications of Programmable Logic Controller
The programmable logic controller (PLC) is a digital operation controller with microprocessor for automatic control, which can load control instructions into memory for storage and execution at any time.
-
09/11/2020
What are the tips for using screw air compressors
The set unloading pressure of the air compressor pressure regulator is adjusted with the upper adjusting bolt. Turn the bolt clockwise to increase the unloading pressure, and rotate it counterclockwise to reduce the unloading pressure. The differential pressure value is adjusted by the differential knob at the bottom. Turn it counterclockwise, the pressure differential value of the air compressor decreases, and clockwise
-
08/14/2020
How much do you know about water-cooled chillers A few steps let you know
What is the cooling method of the chiller? A water-cooled chiller is one of them. It has many names. Some people say it is a chiller or a chiller. No matter which type, it is the same machine.
-
08/13/2020
Adding method of refrigerant in central air conditioner
How to add refrigerant to central air-conditioning, what operating methods do you know? Let’s take a look with the editor of okmarts.com today!
-
03/13/2021
Working mode of servo driver
The working modes of servo driver are: open loop mode, voltage mode, current mode (torque mode), IR compensation mode, Hall speed mode, encoder speed mode, tachometer mode, and analog position loop mode (ANP mode). (not all of the above modes exist in all models of drives)
-
08/17/2020
What is the principle of the chiller shell and tube evaporator
The cold water shell and tube evaporator is made by expanding two-layer metal plates with high-pressure gas or by mechanical pressing. It can also be made of aluminum alloy die-casting.
-
04/06/2022
How to Make an Air Conditioner With a Fan?
The weather in summer is pretty hot . If there is no air conditioner at home, only the electric fan can we use to cool down. If we still feel hot after turning on the fan, in fact, we can make an electric fan as cool as an air conditioner by ourselves.
-
07/23/2020
How to reduce the discharge temperature of refrigeration compressor
The refrigeration compressor is the core and heart of the refrigeration system. The capacity and characteristics of the compressor lead to the capacity and characteristics of the refrigeration system. In a sense, the design and matching of the refrigeration system is to reflect the capacity of the compressor.
-
06/26/2022
How to Test an Encoder with a Digital Multimeter
A basic multimeter can be utilized to measure the encoder’s parameters. Bear in mind that a digital multimeter can measure the average duty cycle, frequency, peak voltage, and average voltage of an encoder.
-
07/17/2020
Cause Analysis and Treatment Method of Copper Tube Leakage of Evaporator of Single Cooling Unit
Cause Analysis and Treatment Method of Copper Tube Leakage of Evaporator of Single Cooling Unit A central air-conditioning system in a public area uses a screw chiller. During operation, a copper tube in the evaporator leaks due to a malfunction. After further inspection by the technical staff, it was confirmed that the fault was leakage of the copper pipe of the evaporator of the chiller.