Stroke: 3 mm - 2000 mm
Piston diameter: 100 mm
Type code: DNC
Based on norm: ISO 15552
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Design: Piston: Piston rod: Profile barrel
Position sensing: None: For proximity sensor
Variants: With end-position locking at both ends: Continuous, hollow piston rod: Monostable pneumatic valve, fitted on left, piston rod extended when not actuated: Monostable pneumatic valve, mounted on right, piston rod retracted when not actuated: With front end-position locking: Temperature range -40 to 80 Celsius Degree: Through piston rod: Piston rod with external hexagon: Constant, slow movement: Bistable pneumatic valve, fitted on left, piston rod retracted when not actuated: Increased service life: Extended external thread piston rod: With anti-twist protection: High corrosion protection: With rear end-position locking: Special thread on piston rod: Bistable pneumatic valve, fitted on right, piston rod retracted when not actuated: Dust protection: Piston rod at one end: Monostable pneumatic valve, mounted on left, piston rod retracted when not actuated: Clamping unit on the piston rod: Heat-resistant seals max. 120Celsius Degree: Monostable pneumatic valve, fitted on right, piston rod extended when not actuated: Internal thread on piston rod: Low friction: Extended piston rod
Protection against torsion/guide: Square piston rod
Operating pressure: 0.12 bar - 12 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 1 (ATEX): Zone 2 (ATEX): Zone 22 (ATEX): Zone 21 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 3 - High corrosion stress: 2 - Moderate corrosion stress
Ambient temperature: -40 to 120 Celsius Degree
Impact energy in the end positions: 1.2 J
Max. torque for protection against rotation: 3 Nm
Theoretical force at 6 bar, retracting: 4418 N
Theoretical force at 6 bar, advancing: 4418 N - 4712 N
Type of mounting: With internal thread: With accessories
Pneumatic connection: G1/2
Note on materials: RoHS-compliant
Cover material: Coated: Die-cast aluminum
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Festo Air Cylinder DNC-100-125-PPV-A-S6
People who bought this item also viewed
CHANTO Air Cylinder JUR25X15
CKD Air Cylinder SCPG2-M-00-10-30
AirTAC Air Cylinder JSI100X400S
Festo Air Cylinder ADN-80-40-A-P-A
Festo Air Cylinder CLR-40-10-R-P-A
Festo Air Cylinder ADN-16-80-A-P-A
Festo Air Cylinder DNC-40-90-PPV-A-KP
Festo Air Cylinder EMM-32-15-P-A
MINDMAN Air Cylinder MSBS-32-20
CKD Air Cylinder SCA2-00-50B-50
Festo Air Cylinder DPZJ-20-40-P-A-S2
Autonics Rotary Encoder ENH-100-1-L-5
AirTac Solenoid Valve 4V210-08-B
Honeywell Actuator ML7984A4009/U
SMC Proportional Valve ITV2050-013CS
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Meas Transmitter M517X-C25002-250BG
YEESEN Vane Pump PV2R2-75-FR
BOSCH Flowmeter 028100295 23918074
Recent related posts
-
03/19/2024
Servo Motor vs. Stepper Motor: Unraveling the Differences and Choosing the Right Fit
In the realm of automation and precision control, the choice between servo motors and stepper motors plays a pivotal role in determining the efficiency and accuracy of various systems.
-
07/08/2023
Heat Pump Compressor Not Running: Common Issues and Solutions
A heat pump is an energy-efficient heating and cooling system that relies on the process of heat transfer to maintain comfortable indoor temperatures.
-
08/22/2022
Speed-Torque Curve of Stepper Motors and FAQs
This is the torque the motor will produce when the motor is stationary and rated current is applied to the windings.
-
09/02/2020
7 reasons for high oil consumption of air compressors
Run oil In our daily work, we often encounter the problem of running oil in air compressors. In addition to the quality of the oil content, what other reasons can cause running oil? Engineers have summarized several reasons that can cause running oil in practice. The following okmarts .com share with you.
-
06/14/2020
Refrigeration compressor failure phenomenon and determination method
Refrigeration compressor failure phenomenon and determination method 1. How to identify the three binding posts on the casing of the hermetic compressor? Running end (R), starting end (S), common end (C), the resistance between RS is greater than that 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇
-
09/03/2020
German dairy giant highly praises Ultima compressor
ULTIMA new generation innovative oil-free compressor German dairy giant highly praises Ultima compressor Ultima works perfectly, a compressor that satisfies all your fantasies
-
06/14/2020
Leading the future of electrification, Danfoss wins new orders in the field of new energy ships
A few days ago, Danfoss signed an agreement with China Shipbuilding Corporation 711 Research Institute to provide EDITRON permanent magnet synchronous reluctance auxiliary motors, frequency converters and DC/DC converters for the institute, and to propel 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈
-
06/14/2020
Technical status and development trend of refrigeration and air-conditioning compressors
Refrigeration machinery and air conditioning equipment play a very important role in the development of the national economy, the improvement of people's lives and the support of national defense equipment.
-
06/29/2020
Analysis of the cause of excessive suction temperature of compressor
Analysis of the cause of excessive suction temperature of compressor The high suction temperature is mainly due to the increase of superheat of suction. Note that high suction temperature does not mean high suction pressure, because the suction is superheated steam. Under normal circumstances, the compressor cylinder head should be half cold and half hot. If the suction temperature is too high, the cylinder head will all heat up.
-
09/15/2020
Adjustment of main machine clearance of twin screw compressor
I repaired a main engine with locked rotor in the early stage. It is an EP200 model produced by Ingersoll Rand in 1997. Before I repaired it, Ingersoll Rand itself could not repair it. Because the main engine was severely deformed and the rotor and cavity Severe body adhesion.