Stroke: 2 mm - 2000 mm
Piston diameter: 32 mm
Type code: DNC
Based on norm: ISO 15552
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Design: Piston: Piston rod: Profile barrel
Position sensing: None: For proximity sensor
Variants: Bistable pneumatic valve, fitted on right, piston rod retracted when not actuated: Continuous, hollow piston rod: Extended external thread piston rod: With anti-twist protection: Piston rod at one end: Through piston rod: Increased service life: With rear end-position locking: Temperature range -40 to 80 Celsius Degree: Extended piston rod: Clamping unit on the piston rod: With front end-position locking: Low friction: With end-position locking at both ends: Monostable pneumatic valve, mounted on left, piston rod retracted when not actuated: High corrosion protection: Internal thread on piston rod: Dust protection: Piston rod with external hexagon: Monostable pneumatic valve, mounted on right, piston rod retracted when not actuated: Constant, slow movement: Heat-resistant seals max. 120Celsius Degree: Monostable pneumatic valve, fitted on right, piston rod extended when not actuated: Bistable pneumatic valve, fitted on left, piston rod retracted when not actuated: Monostable pneumatic valve, fitted on left, piston rod extended when not actuated: Special thread on piston rod
Protection against torsion/guide: Square piston rod
Operating pressure: 0.2 bar - 12 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 22 (ATEX): Zone 1 (ATEX): Zone 2 (ATEX): Zone 21 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 2 - Moderate corrosion stress: 3 - High corrosion stress
Ambient temperature: -40 to 120 Celsius Degree
Impact energy in the end positions: 0.1 J
Max. torque for protection against rotation: 0.8 Nm
Theoretical force at 6 bar, retracting: 415 N
Theoretical force at 6 bar, advancing: 415 N - 483 N
Type of mounting: With internal thread: With accessories
Pneumatic connection: G1/8
Note on materials: RoHS-compliant
Cover material: Coated: Die-cast aluminum
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Festo Air Cylinder DNC-32-125-PPV-A-KP
People who bought this item also viewed
CKD Air Cylinder SCPG2-M-00-10-30
Festo Air Cylinder DSNU-10-65-P-A-MQ
Festo Air Cylinder ADNGF-63-25-P-A
Festo Air Cylinder ADN-32-50-A-P-A
Festo Air Cylinder ADNGF-32-15-PPS-A
Festo Air Cylinder DNC-63-160-PPV-A-KP
Festo Air Cylinder DFM-20-80-B-PPV-A-KF
AirTAC Air Cylinder HLH16X50S
MTL Encoder MAH-42-4096G5
AirTac Solenoid Valve B03-4V430E-15A
Belimo Actuator NMU24-T
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
NMB-MAT Fan BT1002-B044-00S
VTOOL Tool for Metal Cutting C32-20
SCHRACK Relay MT321220
NORGREN Filter 5311-03
LONGBattery WP26-12B
Recent related posts
-
09/10/2020
The actual displacement of the screw compressor is affected by those factors
1) Leakage. There is no contact between the rotors and between the rotor and the housing during operation, and a certain gap is maintained, so gas leakage will occur. When the pressure increased gas leaks to the suction pipe and the sucking groove through the gap, the exhaust volume will be reduced.
-
02/23/2021
What to do if Haier refrigerator doesn't cool
In the process of using home appliances, there will be some situations. I believe many people have encountered that the refrigerator at home is not cooling. What will you do when you encounter this situation? Let’s take a look at Haier with the editor. What to do if the refrigerator is not cooling, for your reference.
-
06/14/2020
Knowledge of maintenance of air energy heat pump
Knowledge of maintenance of air energy heat pump The air energy water heater is composed of an outdoor unit and an insulated water tank. The outdoor unit is called an air energy heat pump unit.
-
08/17/2020
The specific maintenance content of the cooling tower equipment of the chiller
We know that the international cooling water tower is a structure used for cooling water in power plants, and the general height is determined by the size of the power plant units.
-
06/14/2023
6 Ways to Quiet Your Noisy Refrigerator Compressor
A noisy refrigerator compressor can be a source of irritation for homeowners, especially if the appliance is located in a common area of the home.
-
01/22/2023
How to Deal with Spindle Amplifier Alarm Codes?
When faults occur, there will be various alarm codes on the Spindle amplifier, each representing different faults.
-
07/15/2020
ZP57KUE-TFD4.8HP 60Hz (R410A) air conditioning operating conditions Emerson Copeland compressor
Today I want to introduce the Emerson Copeland compressor ZP57KUE-TFD for R410A refrigerant in 60Hz three-phase electric air conditioning. The power given in the manual of Emerson Copeland Scroll Air Conditioner Compressor is 4.8 hp, and other technical parameters can be downloaded from our company's website to download the product manual.
-
09/08/2023
Air Source Heat Pumps Explained
Air source heat pumps (ASHPs) have emerged as a popular and eco-friendly alternative for heating and cooling homes.
-
06/26/2022
Applications of Encoder
Encoders are critical components in all kinds of mechanical systems. They are especially prevalent in industrial settings where large machinery performs repeatable tasks
-
06/14/2020
Give home N95 level protection, home fresh air system, real breathing enjoyment!
Give home N95 level protection, home fresh air system, real breathing enjoyment! After the epidemic, the fresh air system once again refreshed people's understanding.