There is no price at present, you can Request a Quote
Inlet/Outlet diameter: 80/65 mm
Pumping head: 35 m
Flow rate: 850 L/min
Motor power: 11 kW
Shaft power: 2800
Voltage: 380V
Suction head: 7 m
Galileo Magnet Pump 80CQ-35
There is no price at present, you can Request a Quote
People who bought this item also viewed
PAN WORLD Magnet Pump NH-400PW-P-RV
VACUTRONICS Vacuum Pump DP-180V
ARO Diaphragm Pump 666100-889-C
KMP Water Pump EMP-545
TTO Mechanical Seal 45×60×10
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SMC Solenoid Valve SY7220-5DD-C8
Toho Temperature Controller TTM-107-0-RN
Honeywell Sensor AWM5103VN
YUKEN Vane Pump PV2QR3-94-F-RAA
Eaton Vickers Vane Pump V10-1B4B-1D20
Recent related posts
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/14/2020
Screw refrigeration compressors are prone to these types of failures, have you ever encountered them
1. Fault type 1. Abnormal compression ratio 2. Low condenser efficiency and failure 3. Low evaporator efficiency and failure 4. Failure of the oil system 5.Electrical failure
-
10/13/2021
Common Types of Refrigeration Compressors: A Comprehensive Guide
When mentioning refrigeration, everyone in this modern world may be familiar with it. People's daily use of air conditioners, refrigerators, whether small household or large commercial ones, are refrigeration appliances.
-
09/18/2020
Jingliang Electronics-Air Compressor Sensor Solution
——High-quality, cost-effective to provide customers with perfect sensor solutions Precision Electronics-MEAS (MSI) Sensor Co., Ltd. is a precision electronic engineering expert who masters the world's leading silicon micromachining MEMS technology.
-
04/13/2023
15 Refrigeration System Components Structure, Function, Working Principle Diagram (1)
There are four main components in the refrigeration system, namely compressor, condenser, throttling device (such as capillary tube, expansion valve), evaporator.
-
08/02/2020
What is the four-pipe air conditioner Under what circumstances
Four-pipe air-conditioning means that the air-conditioning box is equipped with cold coils and hot coils at the same time. Each group of coils is fed one time, a total of four, so it is called four-pipe.
-
07/16/2020
Three factors determine the quality of cold storage
The size of the cold storage should be designed according to the highest amount of agricultural products to be stored throughout the year. This capacity is calculated based on the volume that the stored products must occupy in the cold storage, plus the aisles between the rows, the space between the stack and the wall and ceiling, and the gap between the packaging.
-
03/17/2021
Several common faults in the spindle drive system of CNC machine tools and how to repair it?
When the vertical machining center supporting FANUC6 system is working, the machine tool vibrated severely, and the AC spindle drive displayed AL-04 alarm. During the vertical machining center supporting FANUC6 system is working, the machine tool vibrates severely, and the AC spindle drive displays AL-04 alarm.
-
07/28/2020
Condenser cleaning judgment, method and operation are all here!
Condensers are prone to scale formation in the pipes after long-term use. If they are not treated in time, these scales will affect the heat exchange effect and cause the condensing temperature of the unit to increase,
-
07/22/2020
The refrigerator is not cooling, and the compressor ‘buzzes’ after turning on the battery for a few seconds. What's the matter?
A few days ago, I received a call from a customer asking for repairs, saying that her refrigerator had suddenly stopped cooling in the past two days. The light bulb in the plug-in fresh-keeping room was on, and no movement was heard.