Series | MCFA Series |
Symbol Style | Double action / Male thread |
Tube I.D. (mm) | 16 |
Stroke (mm) | 15 |
TYPE | Standard |
PORT THREAD | M5×0.8 |
Acting type | Double acting |
Tube I.D.: 16mm
Medium: Air
Max. operating pressure: 0.7 MPa
Proof pressure: 1 MPa
Ambient temperature: -5 - 60 degree celsius(No freezing)
Lubrication Not required
Available speed range: 50-500 mm/sec
Cushion: With rubber cushion pad We can also provide the following models
MCMJ-27-6-30M-20-G
MCJQ-14-63-45M-G
MCJQ-24-20-5M-G
MCMJ-28-10-100M-20-G
MCQI2-27-40-125M-20
MCMI-13-40-15-A-F
MCSS-25-75-BT-X12-NPT
MCMI-27-32-100-N
MCMI-13-12-80-A-F
MCDA-23-25-125-G
MCGS-27-32-50-20-NPT
MCJQ-27-63-125M-F
MCCG-28-100-600M-30-G
MCJQ-11-32-200M-NPT
MCFA-11-20-25M-NPT
MCJQ-16-40-45M
MCMB-13-20-300-XB4H
MCSS-25-100-AB-X11-NPT
MCMI-27-8-50-F
MCMI-11-25-200-A-NC
For more information,please contact us freely
MINDMAN Pneumatic Equipment Air Cylinder MCFA-11-16-15M
People who bought this item also viewed
Compact Air Cylinder SD34X12
Festo Air Cylinder DGP-32-600-PPV-A-B
MINDMAN Air Cylinder MCJT-32-12-45-50M
MINDMAN Air Cylinder MCSH16-30
MINDMAN Air Cylinder MCQA-11-80-25
MINDMAN Air Cylinder MCGS-23-40-25
SHAKO Air Cylinder TC63B200
Festo Air Cylinder ADVUL-63-10-P-A
Festo Air Cylinder ESNU-25-50-P-A
Autonics Rotary Encoder E50S8-100-6-V-24
CKD Solenoid Valve 3PB210-08-3
SIEMENS Actuator SSA61
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Festo Solenoid Valve MHP2-MS1H-5/2-M5
Panasonic Servo Motor MDME152GCHM
Recent related posts
-
09/10/2020
The actual displacement of the screw compressor is affected by those factors
1) Leakage. There is no contact between the rotors and between the rotor and the housing during operation, and a certain gap is maintained, so gas leakage will occur. When the pressure increased gas leaks to the suction pipe and the sucking groove through the gap, the exhaust volume will be reduced.
-
08/04/2021
Mitsubishi Vs. Panasonic Air Conditioners
Summer is so difficult to spend that people without the air conditioner are like fish out of water. It’s critical to choose a good air conditioner.
-
07/19/2020
Advantages of adding economizer to screw chiller
The temperature control range of the standard screw chiller is 3~35℃, and the efficiency is significantly reduced when operating under lower temperature conditions. In order to meet the temperature requirements of more industries for chillers, make the single-stage screw compressor work according to the two-stage refrigeration cycle and achieve the effect of energy saving, an economizer can be added to the unit.
-
07/29/2020
Adding fluoride to the air conditioner is tricky, don't be fooled!
remind<br></br> In the hot weather, many citizens have begun to use air conditioners to remind everyone to be careful not to be fooled by unnecessary "air conditioner filling
-
06/14/2020
Do you know several common refrigeration compressors
Among various types of refrigeration compressors, piston compressors are the earliest and still have more models. For example, semi-hermetic piston refrigeration compressors are widely used in refrigeration and refrigeration equipment. Common manufacturer 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ
-
07/11/2020
Working principle structure diagram of screw air compressor
Working principle structure diagram of screw air compressor 1. The basic structure and working principle of screw air compressor The commonly known screw compressor refers to the twin screw compressor. The basic mechanism of screw compressor: In the body of the compressor, a pair of intermeshing spiral rotors are arranged in parallel.
-
07/05/2020
Hitachi Air Energy Heat Pump Compressor
Hitachi Air Energy Heat Pump Compressor The compressor does not start and has nothing to do with the four-way valve coil heating mode Why can't the compressor of the four-way valve of the air conditioner start up after changing the heating mode? The compressor does not start and has nothing to do with the four-way valve coil heating mode.
-
09/10/2020
How to choose the specifications of the air compressor
Once the air volume (m3/min) and pressure (Mpa(G)) requirements of the factory's air consumption are determined, the specifications of the air compressor can be selected. Factors you may want to consider when choosing include:
-
06/22/2023
What is a DC Compressor? A Comprehensive Guide
A DC compressor is an electrical compressor that is powered by direct current (DC) electricity.
-
08/15/2020
The price of industrial chiller is too low, what should you pay attention to
Industrial chillers are commonly used temperature control equipment and are used in various industries. Therefore, the requirements for use are also different. The requirements for laser and