What factors will cause the cooling performance of water-cooled chillers to decline
Water-cooled chillers are especially suitable for places with abundant water resources. The operation is more stable. It has the characteristics of large single-unit cooling capacity and high cooling efficiency. Therefore, it is often used in chemical plants, pharmaceutical plants, electroplating plants, etc. that require large cooling capacity industry.
When water-cooled chillers are in use, they need supporting cooling towers and water pumps for heat dissipation to provide circulating cooling water. The installation is a bit more complicated than air-cooled chillers. The next thing I want to introduce to you is the factors that cause the cooling performance of the water-cooled chiller to decline, let's take a look.
1. Part of the factor is that the water source used by the water-cooled chiller has impurities. After a long period of time, it has accumulated and adhered to the pipes between various equipment, resulting in a small water flow. Therefore, it is necessary to clean the pipes between the equipment;
2. As far as the chiller factory is concerned, all chillers will undergo performance testing before leaving the factory to ensure the normal operation of the unit. If the indoor temperature cannot be lowered during the first use, it is possible that the water-cooled chiller is not equipped correctly;
3. The temperature of the cold-water chiller cannot be lowered when it is used for the first time. Another reason is that there is a small problem in the installation between the water-cooled chiller and the cooling tower, circulating water pump, and pipeline, which requires careful investigation according to the installation diagram;
4. If the cooling performance of a water-cooled chiller that has been used for half a year or a year has decreased, there may be several problems: the heat exchanger of the water-cooled chiller is too dirty, and it is recommended to clean the heat exchanger (fin heat exchanger). Or shell and tube heat exchanger), and clean it regularly during subsequent use; the refrigeration system of the chiller leaks freon, it is recommended to find the leakage point, repair welding, and add refrigerant; it may be that the environmental temperature of the chiller is relatively bad. If it is too high or too low, the water-cooled chiller cannot meet the requirements. In this case, the requirement can only be met by choosing a larger water-cooled chiller.
In the face of water-cooled chillers with reduced cooling performance, if the user does not have professional maintenance personnel, do not handle it without authorization, but should contact the original chiller manufacturer to arrange professional technicians, or find professional maintenance near the factory For users with poor water sources, it is recommended to filter the water quality or do professional water treatment; in addition, users should do regular maintenance on the unit, which can not only ensure the normal operation of the unit.
Water chillers have been more and more widely used in all walks of life around us. Its main function is to provide industrial chilled water for equipment or products. The use of water-cooled water chillers to reduce the temperature not only improves production efficiency, but also reduces Cost of production. In the face of abnormal problems with water-cooled chillers, they must be dealt with in time, and attention must be paid to maintenance and cleaning in daily use, which also effectively improves the service life of the equipment.
What factors will cause the cooling performance of water-cooled chillers to decline
Recent related posts
-
08/16/2020
What factors will cause the cooling performance of water-cooled chillers to decline
Water-cooled chillers are especially suitable for places with abundant water resources. The operation is more stable. It has the characteristics of large single-unit cooling capacity and high cooling efficiency.
-
08/16/2020
What is the difference between a water source heat pump and a water ring heat pump
1. Water source heat pump technology Water source heat pump technology is a low-temperature low-level thermal energy resource formed by using solar energy and geothermal energy absorbed from shallow water sources on the earth's surface
-
08/16/2020
What is the emergency treatment method for R22 refrigerant leakage
R22 refrigerant has low toxicity, but some of the cracked gas and residual liquid components produced by using it to prepare tetrafluoroethylene are highly toxic, which can cause acute poisoning.
-
08/16/2020
What is the new refrigerant of R410A and what are its advantages in air conditioning applications
Recently, many users are familiar with the term inverter air conditioner, but do they feel strange to another term—new refrigerant? In fact, new refrigerant is just a kind of refrigerant that air conditioners must have when running.
-
08/16/2020
What is the structure of the fan coil
The fan coils we usually touch mainly include horizontal concealed fan coils, horizontal surface mounted fan coils, vertical surface mounted fan coils, vertical concealed fan coils, and other methods.
-
08/16/2020
What parameters should be understood when choosing a central air-conditioning air-cooled heat pump unit
You must be familiar with central air-conditioning, but did you know that there is a unit in central air-conditioning called a cold and heat pump unit? The work of central air-conditioning is inseparable from it.
-
08/16/2020
What should I do if the screw of the rod-type chiller bites to death
Screw chillers are widely used in industry and chemical industry. Screw chiller is just one type of screw refrigeration series. There are also medium and low temperature screw chillers, air-cooled screw chillers,
-
08/16/2020
What to pay attention to when the refrigeration equipment is moved
Because the company needs to change the working environment, all the equipment of the company must be moved, and the refrigeration equipment in the disassembly and installation process requires staff with rich professional knowledge,
-
08/16/2020
Where is the key technology of ammonia refrigeration system construction
1. Refrigeration compressor installation Before the refrigeration compressor is in place, clean the soil and dirt from its bottom and foundation bolt holes, and clean up the foundation surface that has passed the acceptance.
-
08/16/2020
Why is the temperature too low after the cold storage is installed
After the cold storage is built, the first thing should be tested, so that we can know whether there will be problems after the cold storage is installed. Such a problem needs to be considered in the initial stage of the general cold storage installation.
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
HENGYI Vane Pump SVPF-12-55-20
VIGOR PLC VH-20AR
HYDROMAX Gear Pump HGP-1A-L2.6L
SUNX Sensor DP-Y27Z
Schneider Sensor XMLP016BD11VQ
SHAKO Air Cylinder PCL40C175