What is the structure of the fan coil
The fan coils we usually touch mainly include horizontal concealed fan coils, horizontal surface mounted fan coils, vertical surface mounted fan coils, vertical concealed fan coils, and other methods. The coils are all evolved from these types of coils or slender. Therefore, we analyze the structure of fan coils based on these types of coils:
(1) Condensate drain pan
The function of the water receiving pan is to collect the condensed water from the fan coil, and connect the condensate pipe to discharge the condensed water. When the coil cools and dehumidifies the air, the condensed water that occurs will drip into the drip tray (also known as the drip tray, the drip tray) and be discharged through the drain.
(two) coil
The cold (hot) medium water in the coil is collected and supplied by the machine room. The control switch turns on the two-way solenoid valve. The cold (hot) medium water flows through the coils, and after heat exchange, the cold or hot air is sucked out.
(three) motor
There are two types of fan coil motors, two-axis motors and single-cycle motors, three-speed conversion and start-stop, the red line is connected to high speed, the blue line is connected to medium speed, and the black line is connected to low speed. There are several other ways for the motor based on the current, which is also the primary component that affects the life of the fan coil.
(four) air conditioning fan
Air-conditioning fan The air-conditioning fan is mainly composed of a casing, an impeller and an air inlet.
Machine shell: All parts are made of galvanized steel sheet or excellent cold-rolled sheet. Its shape is smooth, heat-resistant, moisture-resistant, and durable.
Impeller: The forward multi-wing circular arc blade is riveted to the front and middle plates, and undergoes strict dynamic and static balance proofreading to ensure stable work, high efficiency and low noise.

Related Info
Why is the temperature too low after the cold storage is installed Where is the key technology of ammonia refrigeration system construction What to pay attention to when the refrigeration equipment is moved What should I do if the screw of the rod-type chiller bites to death What parameters should be understood when choosing a central air-conditioning air-cooled heat pump unitWhat is the structure of the fan coil
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
KOGANEI Air Cylinder DABL40X125-4
Contact Us
SMC Solenoid Valve SYJ5120-6LZE-C6
US$133.92
CHELIC Air Cylinder MRU10*300
US$160.38
Siemens Sensor 3RG4024-3JB00
US$115.00
Panasonic Resistor ERO-S2PHF18R0
Contact Us
IFM Sensor IT5007
US$57.69
SUNON Fan PFE0384BX-0000-G99
US$74.00
Ding Zing Oil Seal UN35*45*6
US$1.54