Fan Type | DC Fan |
Series | H Series |
Voltage | 12 VDC |
Frame Size | 50 mm |
Frame Thickness | 15 mm |
Frame Material | - |
Bearing Type | Vapo |
Speed | Extra Low |
Function | Standard Model |
Size | Square - 50mm L x 50mm H |
Power Current | - |
Power Consumption (WATTS) | 500 mW |
Speed | 3200 RPM |
Air Flow | 7.7 CFM (0.216m3/min) |
Static Pressure | 0.060 in H2O (14.9 Pa) |
Noise | 17.0dB(A) |
Termination | 2 Wire Leads |
IP Rating | - |
Approval Agency | CE, CUR, TUV, UL |
Operating Temperature | 14 ~ 158~F (-10 ~ 70~C) |
Weight | 0.064 lb (29.03 g) |
Size/Size: Square-50mm long x 50mm high
Width: 15.00mm
Airflow: 7.7 CFM (0.216m?/min)
Static pressure: 0.060 inches of water column (14.9 Pa)
Bearing type: Vapo-Bearing?
Fan type: tube shaft type
characteristic:-
Noise: 17.0 dB (A)
Power (W): 500mW
RPM: 3200 RPM
Termination: 2 leads
SUNON Fan HA50151V4-000U-999
People who bought this item also viewed
Ebmpapst Fan R2D250-RA10-15
SUNON Fan SF23080A 2083HSL.GN
SUNON Fan A2175-HBT.TC.GN
SUNON Fan PMD2409PMB1-A
SUNON Fan ME40101V1-000U-A99
Ebmpapst Fan R2E220-AB06-48
Servo Fan D1751S24B9ZP300
Sanyo Denki Fan 109P0424H6D18
Y.S.TECH Fan FD486025EB
Hitachi Compressor ASD086UV-H6AUA
COSEL Power Supply SUS1R54815C
CHINT Transformer HB-150
Siemens Contactor 3RT2016-4AK61
PARKER Filter G02749
Danfoss Sight Glass SG19N
IR Rectifier Module 301CNQ040PBF
Chint Relay NXJ-2ZH(D) AC36V
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
JSCC Speed Reducer 90GK750H
HONEYWELL Butterfly Valve V8BFW16-600+NOM-P8B-E
SEW VFD Frequency Converter 31C055-503-4-00
Balluff Sensor BUS0027
Recent related posts
-
09/05/2020
Common sense of micro vacuum pump
The so-called vacuum refers to a gas state with a pressure lower than 101325Pa in a given space. In the vacuum state, the lean degree of gas is usually expressed by the pressure value of the gas. Obviously, the smaller the pressure value, the thinner the gas. There are various vacuum pumps in the industry. There are prescribed test methods for the performance of various pumps. The main parameters are:
-
08/19/2020
How to distinguish inferior refrigerants What effect does refrigerant purity have on the system
Inferior refrigerants will affect the performance and stability of the system, and more seriously will cause damage to system components and compressors. The following methods can be used to distinguish whether it is a low-quality refrigerant:
-
06/13/2020
Compressor common fault handling
Compressor common fault handling Foam when starting with liquid When the air-cooled compressor is started, the phenomenon that the lubricating oil in the crankcase blisters violently is called liquid start. The basic reason for starting with liquid is 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱
-
06/13/2020
Compressor shutdown for screw compressor repair
Among the many refrigeration compressors, the screw compressor is the most extensive one. When the screw compressor suddenly stops after working for a day, a reasonable treatment method should be carried out to ensure that it can be used normally next tim ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ
-
08/21/2020
What is the difference between a central air conditioning system and a clean air conditioning system
The central air conditioning system is mainly composed of refrigerators, cooling water circulation systems, chilled water circulation systems, fan coil systems and cooling towers.
-
01/14/2021
Refrigerator condenser working principle, function, location, cleaning, classification
A normal refrigerator has many components, but the most important components are the compressor, condenser, evaporator and capillary. Compressors are very familiar and understand, so do you know the refrigerator condenser? It has a very important role in 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱
-
08/04/2020
Analysis of five major problems in current heating management
With the development of society and the continuous improvement of people's living standards, traditional heating methods and management models have become less and less suitable for the development of the times.
-
04/01/2024
Top Five Robot Manufacturers Worldwide
Robotics technology is advancing at an unprecedented speed, completely changing the way we live and work. At the forefront of this transformation are companies leading the innovation and shaping the future of robotics.
-
04/25/2022
How to Install A Surge Protection Device?
Set power line surge protection device at the entrance of the line into the building, the interface of the lightning protection area and the place close to the protected equipment.
-
03/07/2021
AC servo driver wiring precautions
For signal line and encoder input line, please use shielded wire. Wiring length: the length of signal line from NC to AC servo driver is less than 3m, and the length of input line from AC driver to encoder is less than 20m. The ground wire should be thick wire as far as possible. According to the third grounding standard (grounding resistance < 100 Ω), one point grounding method should be adopted to connect the ground wire. If the motor and the machine tool are insulated, the motor should be grounded.