There is no price at present, you can Request a Quote
F.TEC Air Cylinder KTN10-10-100-200
There is no price at present, you can Request a Quote
People who bought this item also viewed
Festo Air Cylinder ADN-20-60-I-P-A
MINDMAN Air Cylinder MCJT-12-20-20
Festo Air Cylinder ADN-32-25-I-P-A
MTL Encoder MEH-85-3600P
Belimo Actuator GRKU24-MF-7
Bellofram Proportional Valve 969-755-000
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Siemens Contactor 3RT2544-1AB00
Yaskawa Servo Drive SGD7S-550A00A202
PIZZATO Switch PX 10810
Recent related posts
-
09/04/2023
Ducted vs Ductless Heat Pump: Which One is Right for You?
When it comes to heating and cooling your home, there are many options available. Two popular choices are ducted and ductless heat pumps.
-
06/28/2020
Trouble analysis and elimination of semi-hermetic compressor motor
Trouble analysis and elimination of semi-hermetic compressor motor Abstract:Semi—hermetic compressor often be used in the water—cooling unit of air conditioning system,and it’S motor which work in rather high temperature and pressure condition,even work with refrigerator and oil, has a poor working condition.
-
09/14/2020
Large oil consumption of the unit or high oil content of compressed air
The amount of lubricating oil is too much. The correct position should be observed when the unit is loaded. At this time, the oil level should not be higher than half;
-
09/02/2020
The working principle of air compressor
The working principle of air compressor<br></br> working principle<br></br> (1) Piston air compressor<br></br>
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/14/2020
HVAC people collect these data, better than ten years of work experience!
HVAC people collect these data, better than ten years of work experience! HVAC people, we know that there are many systems in the HVAC project, and the situation is complicated, and most of the pipelines are hidden in the tube wells, walls, and suspended 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ь 識
-
01/11/2023
What is a Directional Control Valve?
Hydraulic valves are used to control the flow direction or adjust the flow and pressure of liquids (oil, water, or air) in hydraulic systems.
-
08/12/2020
Precautions for the use of ultra-low temperature storage boxes
The ultra-low temperature storage box is shipped after more than 12 hours of debugging before leaving the factory. Today, the editor of the ultra-low temperature storage box okmarts.com will share with you, there are some problems that should be paid atte¨ﰨ2 䀀 湠疨 V ǜ
-
07/11/2022
How to Choose an Air Compressor
Choosing an air compressor can leave you feeling lost if you don't know what to look for. That's because air compressors power a wide range of tools over a wide range of applications.
-
01/05/2024
Cooling Methods for DC Charging Piles and Selection of Cooling Fans
Compared to other power sources, charging stations (charging piles) have much greater heat dissipation requirements, making the thermal design of the system extremely strict.