Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 100 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 80...100 A |
Suitable for induction motors with P | 45 kW |
Instantaneous overcurrent releases | 1235 A |
Short-circuit breaking capacity | 50 kA |
Weight approx. | 2.295 kg |
Circuit breaker size S3 for motor protection, Class 10 A-release
80...100 A Short-circuit release 1235 A Screw terminal Standard
switching capacity !!! Phased-out product !!! Successor is SIRIUS
3RV2 Preferred successor type is >>3RV2041-4MA10<<
product brand name SIRIUS
product designation circuit breaker
design of the product for motor protection
General technical data
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 44 W
at AC in hot operating state per pole 14.7 W
surge voltage resistance rated value 6 000 V
protection class IP
on the front IP20
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 50 000
continuous current rated value 100 A
Ambient conditions
installation altitude at height above sea level
maximum
2 000 m
ambient temperature
during operation -20 ... +60 degrees centigrade
during storage -50 ... +80 degrees centigrade
during transport -50 ... +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent
overload release
80 ... 100 A
operating voltage
rated value 690 V
at AC-3 rated value maximum 690 V
operating current
at AC-3
at 400 V rated value 100 A
operating power
at AC-3
at 400 V rated value 45 kW
operating frequency
at AC-3 maximum 15 1/h
Auxiliary circuit
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 50 kA
at AC at 500 V rated value 8 kA
at AC at 690 V rated value 5 kA
Short-circuit protection
design of the overcurrent release and short-circuit
release
thermomagnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 50022
height 165 mm
width 70 mm
depth 174 mm
required spacing
with side-by-side mounting
backwards 0 mm
at the side 0 mm
Connections/ Terminals
product function
removable terminal for auxiliary and control
circuit
No
type of electrical connection
for main current circuit screw-type terminals with box terminals
for auxiliary and control circuit screw-type terminals
arrangement of electrical connectors for main current
circuit
front side
type of connectable conductor cross-sections
for main contacts
solid 2x (2.5 ... 16 mm?)
stranded 2x (10 ... 50 mm?), 1x (10 ... 70 mm?)
finely stranded with core end processing 2x (2.5 ... 35 mm?), 2.5 ... 50 mm?
at AWG conductors for main contacts 2x (10 ... 1), 1x (10 ... 2)
Siemens Circuit Breaker 3RV1041-4MA10
People who bought this item also viewed
Siemens Circuit Breaker 3RV1011-0DA15
Siemens Circuit Breaker 3RV2021-4PA10
Siemens Circuit Breaker 3RV1021-0BA10
ABB Circuit Breaker SH202-C10
Siemens Circuit Breaker 3RV1011-0DA10
Siemens Circuit Breaker 3RV2011-4AA10
Mitsubishi Circuit Breaker AE1600-SW 3P
CHINT Transformer NDK(BK)-100
Siemens Contactor 3RT1075-6AS36
Ferraz Shawmut Fuse PC292UH15C800TF
HONGFA Relay HF14FW-012-HSTF
IRC Resistor 1W 9.89K
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Midea Air Conditioner KFR-51QW-DY-E1(R3)
Recent related posts
-
06/14/2020
The refrigeration master analyzes the phenomenon and cause of compressor liquid blow, you are worth reading!
The refrigeration master analyzes the phenomenon and cause of compressor liquid blow, you are worth reading! The phenomenon that the refrigerant or lubricating oil damages the intake valve piece when the gas is sucked into the compressor cylinder, and do 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ѧ 識 �僬㣢ᐲ 臆S㥲ᐲ
-
09/04/2020
Factors affecting the use of oil-free air compressors
The oil-free air compressor is the main body of the air source device. It is a device that converts the mechanical energy of the prime mover into gas pressure energy and is a pressure generating device for compressed air. The factors that affect its use are:
-
09/10/2020
Lubrication characteristics and requirements of mobile air compressors
1. The characteristics of the mobile air compressor are: (1) The mobile air compressor should be easy to move frequently, the working conditions are changeable, and the load changes greatly. (2) Mobile air compressors are mostly heavy-duty, medium-speed or low-speed transmission, and most require frequent starting and often withstand shock loads;
-
07/14/2020
I realized that in winter, the refrigerator should be adjusted correctly, and the power saving and cooling are correct.
I realized that in winter, the refrigerator should be adjusted correctly, and the power saving and cooling are correct. I believe that there should be a refrigerator in the home of the friends, the role of the refrigerator is to freeze and refrigerate the food in the home.
-
03/02/2021
Advantages and disadvantages, function and service life of brushless motor
Advantage: (1) No brush, low interference When the brush is removed from the brushless motor, the most direct change is that there is no electric spark generated when the brushless motor is running, which greatly reduces the interference of electric spark to the remote control radio equipment.
-
09/22/2020
Features of frequency conversion air compressor
6.1. Save energy? Reduce electricity consumption? Improve corporate competitiveness 7.§Air compressors and air conditioners often account for more than 30% of the company's electricity consumption.
-
07/18/2022
How to Install the Gear Pump
Before installing the gear pump, please check whether the pump and motor are damaged during transportation, or dirt enters the pump cavity due to the loss and rupture of the dust cover.
-
08/18/2020
Air-cooled chiller inspection steps and solutions
Generally, after using the air-cooled chiller for a long period of time, some problems cannot be avoided. If there is a failure, we should carefully check the operating conditions of the various parts of the machine.
-
09/10/2020
The management method of the air compressor room of the Red Fifth Ring
1. Choose a wide and well-lit place to facilitate the space and lighting required for the operation, maintenance and repair of the air compressor.
-
07/15/2022
Common Faults of Gear Pump
Cause: A. the rotation direction is opposite; B. the suction or discharge valve is closed